HomeMy WebLinkAbout01.23.01 Special Planning Packet
,e
e
.
CITY OF FARMINGTON
PLANNING COMMISSION AGENDA
Special Meeting
January 23, 2001 at 7:00 P.M.
1.
CALL TO ORDER
2.
APPROVAL OF MINUTES
a)
December 12, 2000
3.
PUBLIC HEARINGS
a)
Charleswood 5th Addition Preliminary and Final Plat (continued)
Applicant: Newland Communities
b)
Conditional Use Permit Application - Construction of Public Buildings within R-
1 (Low Density) Zoning District
Applicant: City of Farmington
c)
Variance Permit Application - Encroach Ten (to) Feet into Front Yard Setback along
19Sth Street W. - Police Station
Applicant: City of Farmington
4. DISCUSSION
a) Vennillion Grove Final Plat (continued)
Applicant: Rottlund Development
5. ADJOURN
Planning Chair:
Planning Commissioners:
Dirk Rotty
Todd Larson, Chaz Johnson, Ben Barker, Dan Privette
City Staff:
David L. Olson, Community Development Director
Lee Smick, Planning Coordinator
Michael Schultz, Associate Planner
.
.
.
City of Farmington
325 Oak Street. farmington, MN 55024
(651) 463-7111 fax (651) 463-2591
www.ci.farminltOn.mn.us
TO:
City Planning Commission
Michael Schultz fPt>
Associate Planner
FROM:
SUBJECT:
Charleswood 5th Addition Preliminary and Final Plat
DATE:
January 23, 2001
INTRODUCTION
The developer has requested that the continued public hearing for the Charleswood 5th Addition
Preliminary and Final plat be tabled until the February 13,2001 Planning Commission meeting in
order to allow the developer's engineers to make the necessary revisions to the 200th Street
W./Pilot Knob Road intersection.
DISCUSSION
City staff recommended to continue the public hearing at the January 9, 2001 Commission
meeting to allow the developer time to make the following necessary changes;
1) Amend the Landscape plan excluding Sugar Maples with another tree species accepted in
Title 10-6-14 (G) 2: Allowable Street Tree Species;
2) The developer adjust the alignment of 200th Street at the intersection of Pilot Knob Road to
allow for at least a 200-foot "stacking and sight distance section"; _
3) Identify the required easement for the existing sanitary trunk line located south of200lh Street
West;
4) Continued coordination with City Staff and Dakota County on the implementation ofturn
lanes at the intersection of CSAH 31 (Pilot Knob Road) and 200th/203rd Streets.
City staff met with Newland Communities and their engineers on January 11th to discuss the
requested changes at which the developer was agreeable to review the possibility ofthe change to
200th Street.
The developer has since excluded the Sugar Maples and replaced them with another acceptable
boulevard tree species. Also, the developer and their engineer have shown preliminary drawings
of the desired 200- foot distance from the edge of roadway from Pilot Knob Road.
City staff and the developer's engineer are continuing discussions on both the needed easements
for the City's sanitary trunk line south of200th Street and the implementation oftum lanes on
CSAH 31.
.
.
.
ACTION REQUESTED
City staff recommend continuing the Preliminary and Final Plat of Charleswood 5th Addition to
allow the developer additional time to make the necessary changes to the plat. The Preliminary
and Final Plat application were submitted on November 29,2000 at which the City has a total of
120 days for the Planning Commission and City Council to both act on the plat.
cc: Steve Juetten, Newland Communities
.
.
.
City of Farmington
325 Oak Street. Farmington. MN 55024
(651) 463-7111 Fax (651) 463-2591
www.d.farminlton.mn.us
TO:
. City Planning Commission
Michael Schultz /), ;()
Associate Planner Jl'Yv
FROM:
SUBJECT:
Variance Pennit Application - Encroach Ten (10) Feet into Front Yard Setback
along 195th Street W.
DATE:
January 23,2001
INTRODUCTION
The City of Fannington is seeking a variance approval to allow for a ten (10) foot encroachment
into the minimum fifty (50) foot front yard setback along minor arterial streets (see attached
Section 10-4-1 (J).
Plannin~ Division Review
Applicant:
City of Farmington
325 Oak Street
F annington, MN 55024
Attachments:
I. Application
2. Applicant's Site Plan
3. Section 10-4-1 (1): Lot Requirements
Location of Property:
-
Southeast corner of Pilot Knob Road and 195th Street W.
Lot Area:
20 acres
Setback Encroachment:
I 0 feet
Required Setback:
50 feet
Surrounding Land Uses:
Single-family to the northwest, institutional to the north,
future multi-family to the west and east, future public
facility to the south of the Police Station.
Existing Zoning:
R-l (Low Density) Residential
Comprehensive Plan:
Institutional
.
e
.
DISCUSSION
The City of Fannington is seeking variance approval to encroach ten (10) feet into the required
fifty (SO) foot front yard setback along 195th Street W.
The building has a star shaped design that has the "wing" of the building jutting out into the front
yard setback. The closest portion of the main building will be 57 feet from the existing ROW line.
The building is constricted by a 100- foot natural gas line easement that is located on the west side
of the proposed building and runs northwest to southeast.
The architects also have had to take into consideration the future construction of a water treatment
facility (with back wash area), future fire satellite station and a clear well, along with needed
setback from the water tower for future painting. The architects are also proposing a stonn water
retention pond on the west side of the gas line easement.
City staff examined the possibility of shifting the building to the south, which would require the
parking lot to the east to be pushed back (toward the future clear well) and possibly would require
the visitor parking (and likely the front door) to be flipped to the north side of the site. The flipping
of the building would also create a less aesthetic appearance with the garage bay doors facing out
to 195th Street W.
The following requirements need to be justified to allow the 10-foot variance:
1) Literal enforcement of this Title would result in undue hardship with respect to the property.
The principal portion of the building meets the minimum setback requirement; and elimination
of the wing that extends into the setback changes the interior building layout significantly.
2) Such unnecessary hardship results because of circumstances unique to the property.
The property is encumbered with a 100-foot wide gas line easement that restricts the desired
use ofthe property for future public needs.
3) The hardship is caused by provisions of this Title and is not the result of actions of persons
presently having an interest in the property.
Section 10-4-1 (1) of the City Code requires a fifty (50) foot setback from minor arterial right-
of-ways for the possible future needs to expand that roadway. As indicated in criteria number
two, the gas pipeline easement constricts the layout of the site.
4) The variance observes the spirit and intent of this Title, produces substantial justice and is not
contrary to the public interest.
The variance request observes the spirit and intent of the City Code in that the majority portion
of the building along 195th Street meets the minimum setback. The variance also is not
contrary to the interest ofthe public.
5) The variance does not pennit a lower degree of flood protection than the flood protection
elevation for the particular area or pennit standards lower than required by State law.
The site does not contain any flood plain.
.
.
.
ACTION REQUESTED
Staff recommends approval of the variance to encroach 10-feet into the required 50-foot front yard
setback along a minor arterial roadway.
Michael Schultz
Associate Planner
cc: John Erar, City Administrator
.
CITY OF FARMINGTON
VARIANCE APPLICATION
Farmington, MN 55024
651-463-7111 FAX 651-463-1611 For office use
Penn it Number
Applicant Name Citv of Farmi ngton
Applicant Address 325 Oak Strf'f't Fi'lrmi ngton MN 55024
Street City State Zip Code
Phone Number (651) 463-7111
Legal Description of Subject Property: (lot, block, plat name, section, township, range)
The north 1303.89 feet of thp wpc:;t 7q? nn feet of the $Olxt~~'t CJllrlrt~r of Spc:ti on
24. Township 114 North. Range 20 West. Dakota County Minnesota.
Current Land Use Agriculture Current Zoning District RI
. Specific Nature of Request/Claimed Hardship: This request is for a Variance to the 50' setback
requirement along County Road 64. IhlS Varlance lS requested due to the hardship
caused by the ENRON gas pipeline easement and future water treatment facility
requ i rements. r
Following Attached: (please check) ,'\/ '!} Proof of Ownership _ Boundary/Lot Survey
N Application fee ($150) _ Copies of Site Plan
AbstractJResident List (adjoining property owners only)
Torrens (Owner's Dublicate Certificate of Title Required)
Property Owner's Signature
Date
For office use only
Request Submitted to the Planning Commission on
Public Hearing Set for: Advertised in Local Newspaper:
Planning Commission Action:
Comments:
_ Approved _ Denied
Conditions Set:
.
Planning Coordinator:
Date:
~: r-- -- - - -- ------ - - -
~ Z FUTURE
..
jl PUMPSI
(V) CONTROL:
If!
<.D
I~ CURB CUT.
I
, !
:-!
~ I 8
I
I , w 01 ~7b+AU r
I It-..
ql I lfu - lTffi 8 FU1
I v BAC~
.
.0' 0'
ro ~ i
(/,I C1.
.
J1 _J
~l I
:)1 I I
~I
I
Jl I POLICE
:r I h FACILITY
FFE: 959.50 ---rS STALL~
I 70.00'
@ CURB CUT
I ----\
I
I
_i --
-
71 ..--
--
- -- ~
:> --
-- __c
. 4
--
Jl -- --
I ---
--- --
--- --
.)1 ,- --
--
---
I . ----- --
I Of; -- ---- . -
-- ---
I -- --
--t-- --
..) --
--
"0: ---
C' ~~ --
---
'<0 6- ---
, .C,k 0...- --
---
,1- ---
--
--
~ 11
---
.~
\~ l1V1SJ 0 SnONiWn.l.Ili:
(\J
......
.--;;::;::;;.:.
-
- --- _._---~ ._- ._--
~
~..,
'..'
-.<.
\",~~,,_. '
;.'
1 0-4-1 1 0-4-1
(H) If underground parking is included as part of townhouse and
apartment developments, a credit of three hundred (300) square feet
per unit will be added for the units provided with basement garages.
(I)
Single- and two-family dwellings shall be erected over a basement
and include a single car garage of at least three hundred (300)
square feet. If a basement is either not possible or not desired, the
construction shall include a double car garage of at least four
hundred forty (440) square feet. (Ord. 086-177.3-17-1986)
*Jl
The minimum front yard setback for all districts adjacent to minor
arterial streets included in the Thoroughfare Plan of the Farmington
Comprehensive Plan, except for those within Section 31, shall be
fifty feet (50') from the planned right-of-way line. (Ord. 095-360,
10-16-1995)
(K)
In the Agricultural (with the exception of agricultural preserves) and
Conservation Districts. a maximum of four (4) dwellings per
quarter/quarter section shall be permitted, provided:
1. The dwelling units are located entirely within one quarter/quarter
section on a separately owned parcel of at least one acre in size.
2. Access to public roads is separated from adjacent driveways on
the same side of the road by a minimum of three hundred thirty feet
(330') and no closer to public road intersections than three hundred
feet (300').
3. Applications for building permits shall be accompanied by a
registered land survey of the parcel, including the location of the
proposed dwelling. (Ord. 086-177, 3-17-1986)
(L) In the R-1, R-2 and R-4 Residential Districts, the total area utilized
by detached private garages shall not exceed one thousand (1,000)
square feet or the square footage of the principal use, whichever is
smaller. All garages must comply with maximum percentage of lot
coverage listed in Table I, Section 10-4-2 of this Chapter. (Ord.
096-378, 8-19-1996)
(M) Except in the case of a planned unit development, not more than one
principal building or structure shall be located on a platted lot or
parcel of land.
(N) Conditions under which solar energy systems will be approved
include findings that:
597
City of Farmington
City of Farmington
325 Oak Street. Farmington. MN 55024
(651) 463-1111 fax (651) 463-2591
www.d.t.arminlton.mn.us
TO:
City Planning Commission
FROM:
Lee Smick, AICP
Planning Coordinator
SUBJECT:
Vennillion Grove Final Plat
DATE:
January 23,2001
INTRODUCTION
This is a continuation from the January 9, 2001 Planning Commission meeting in order to allow
additional infonnation concerning the proposed sanitary lift station to be presented.
DISCUSSION
.
Attached is a memo from Lee Mann, Director of Public Works/City Engineer, identifying the
reasons for recommendation to the lift station option. This infonnation will be presented at the
January 23, 2001 Planning Commission meeting.
ACTION REQUESTED
Review the attached memo from Lee Mann and consider approval of the Vennillion Grove Final
Plat contingent upon Engineering comments and the execution of a Development Contract and
forward this recommendation to the City Council.
Respectfully submitted,
d~
Lee Smick, AICP
Planning Coordinator
cc: Michael Noonan, Rottlund Homes
.
City of Farmington
325 Oak Street, Farmington, MN 55024
(651) 463-7111 Fax (651) 463-2591
. www.ci.farmington.mn.us
.
.
TO: City Planning Commission
FROM: Lee M. Mann, P.E., Director of Public Works/City Engineer
SUBJECT: Vermillion Grove - Sanitary Sewer Service Issues
DATE: January 23, 2001
As requested, following is the discussion and rationale regarding the staff recommendation for a
proposed permanent lift station for the Vermillion Grove Development.
Based on the project's topography and the location ofthe trunk sanitary sewer line, the sanitary sewer
for the Vermillion Grove Development will be routed from the north to the south, southerly through
the Middle Creek Estates Development, to the existing Middle Creek Trunk sanitary sewer. Several
options to route the sewer system to the south were reviewed by staff.
SEWER SERVICE OPTIONS
Option 1
Staff worked with the developer extensively to identify the possibilities for routing a gravity sewer
line through the streets of the subdivision, as per usual City practice. However, due to the
topography of the site, it became evident that routing the sewer through the streets would result in
sewer pipes with depths of up to 50-feet. This situation is highly undesirable due to the cost and
difficulty of maintaining the sewer line and the ramifications to the correction of future problems. If
the sewer ever needed to be excavated for repair, the trench needed to access the sewer line would be
excessively wide. The entire street in the area would need to be removed and significant areas of
front yards and driveways would be impacted.
Option 2
Routing a gravity sewer line behind the homes in the wetland buffer along the DNR protected
wetland (in Middle Creek Estates as well as Vermillion Grove) was also studied. This option would
allow the sanitary sewer line to be installed at reasonable depths. However, installation of the sewer
line along this alignment would necessitate the removal of a significant corridor of trees along the
DNR wetland, leading to significant degradation of the natural environment and wetland. In addition,
a 12-foot wide roadway and extensive retaining walls would be needed to provide the necessary
maintenance access to the sewer line. A variance from the City's wetland ordinance would also be
required since construction activity would be occurring in the wetland buffer.
.
.
e
Option 3
The final option studied would involve installing a permanent lift station that would be located near
the northwest comer of the DNR wetland. The lift station proposed would be a duplex (two-pump),
submersible pump type lift station with fully automatic controls integrated with the City's newly
installed SCADA (Supervisory Control And Data Acquisition) system. The SCADA system is a
computerized system that controls, monitors, records data and provides the alarms for the City's
water and sewer systems mechanical components. The lift station would be equipped with a back-up
power generator to allow operation during power outages. Additionally, the elevation of the lift
station would be designed such that, in the extreme case that all other systems were to fail, the top
hatch elevation of the lift station would be lower than the lowest basement of any the homes that are
connected to the lift station. In other words, in the most extreme case, sewage would flow out of the
top of the hatch of the lift station before it would back up into the homes that flow to it.
STAFF ANAL YSIS/CONSIDERA TIONS
Several considerations were taken into account during staff s determination of the recommendation
regarding this issue. Installing the sewer line 50-feet deep in areas was not considered an option for
the reasons outlined above. The lift station option was considered because of concerns over the
environmental impact the gravity sewer line would have along the wetland. The City's wetland
ordinance and the 2020 comprehensive Plan's states that it is a goal of the City to "manage the City's
unique land and water resources, and thus, raise the City's quality oflife". The removal of the trees
and the need for the roadway and retaining walls along the wetland with the corresponding
maintenance requirements makes it clear that running the sewer line along the wetland is not an ideal
solution.
Staff also considered the City's goal of eliminating as many of the existing lift stations as possible
and not constructing new lift stations. This goal has been discussed generally in the context of the
potential for sewer back-ups that lift stations can present was well as the on-going maintenance
required of the City's more aged stations. The sewer back-up potential is a significant issue with the
City's older lift stations. The design of the stations in the southern area of the City do not incorporate
the same level of safety factor that would be included in the Vermillion Grove lift station. The design
of the lift station in Vermillion Grove as indicated above, brings the level of risk for a sewer back-up
close to the same as for a gravity line. It should be noted that gravity sewer lines also are susceptible
to back-ups.
In addition, replacing some of the older lift stations will mean significant expenditures. The "can"
style of lift station requires total replacement of the lift station at the time the "can" part finally
corrodes to the point functionality of the lift station is impaired. The cost to replace this style of lift
station is approximately $250,000. Thus, the reasoning behind the goal of eliminating this style lift
station is related to both economics and back-up potential. In contrast, the submersible pump style
lift station that is proposed for Vermillion Grove is more economical to maintain, replace and the
design of the lift station significantly reduces the back-up potential compared to the designs of the
City's other lift stations.