Loading...
HomeMy WebLinkAbout10.24.00 Special Planning Packet ) . .~ .' CITY OF FARMINGTON PLANNING COMMISSION AGENDA Special Meeting October 24,2000 at 7:00 P.M. Council Chambers 325 Oak Street 1. CALL TO ORDER 2. PUBLIC HEARINGS a) Variance Application - Minimum Lot Size/Lot Width and Encroach into the required front and side yard setbacks within the I-I (Light Industrial) zoning district Applicant: Bill Sauber b) JIT Powder Coating Variance Applicant: nT Powder Coating Company c) Petition to Rezone A-2 (Agricultural Preserve) to R-l (Low Density Residential) - Donnelly Property Applicant: Robert Donnelly, Jr. 3. DISCUSSION a) Proposed Ordinance - Adult Establishments 4. ADJOURN Planning Chair: Planning Commissioners: Dirk Rotty Todd Larson, Chaz Johnson, Ben Barker, Dan Privette City Staff: David L. Olson, Community Development Director Lee Smick, Planning Coordinator Michael Schultz, Associate Planner . . . City of Farmington 325 Oak Street, Farmington, MN 55024 (651) 463-7111 Fax (651) 463-2591 www.ci.farmin~on.mn.us TO: . City Planning Commission FROM: Michael Schultz Associate Planner SUBJECT: Variance Application - Minimum Lot Size/Lot Width and Encroach into the required front and side yard setbacks within the 1-1 (Light Industrial) zoning district DATE: October 24, 2000 INTRODUCTION The applicant, Bill Sauber, ] 00 3rd Street, is seeking Planning Commission approval on a variance application for minimum lot size and to encroach into the front and side yard setbacks within the 1-1 (Light Industrial) Zoning District. Plannin!! Division Review Applicant: Bill Sauber 300 3rd Street Farmington, MN 55024 Attachments: I. Application 2. Location Map 3. Site Diagrams 4. Section 10-4-2 Location of Property: 3 15 Pine Street Legal Description: Lot 3, Block 31, City of Farmington Lot Area: 22,233 square feet Lot Width: 60 feet Proposed Front Yard Encroachment: 40 feet Proposed Side Yard Encroachment along East property line: 11 feet . . . Proposed Side Yard Encroachment along West property line: 21 feet Surrounding Land Uses: Single-family to the south and east, open lots to the west (multi-family beyond empty lots) and river/park space to the north Current Land Use: Vacant (Recently the property had contained a mobile home and garage) Existing Zoning: I-I (Light Industrial) Comprehensive Plan: Business DISCUSSION The applicant, Bill Sauber, is seeking multiple variances in order to construct a 4,000 square foot (40' x 100') commercial building within the current I-I (Light Industrial) zoning district; the request includes variances for minimum lot size and setback encroachment along the front and side yards of the property. The land use designation within the 2020 Comprehensive Plan indicates commercial use on this lot, and the adjacent lots. Because of the impending rezoning of not only this property, but other properties that do not follow the designated land use within the Comprehensive Plan, staff is anticipating the property will be rezoned to B-2 (General Business), allowing a zero setback from property lines. After discussions with the applicant, it was realized that the submitted site plan was inaccurate, measurements were taken from the curb line and not the property line, resulting in error of 23 feet due to the boulevard. Staff and the applicant have discussed the error and the options available concerning the requested variances. Attached is the submitted site plan and a revised site plan indicating the existing property line. Staff has indicated to the applicant that any proposed off-street parking will not be permitted within the boulevard area, this may result in the building be shifted back and away from the property line, thus reducing the requested encroachment. The applicant is proposing to have at least one (1) off-street parking stall, with an additional parking space in front of the garage door; storage of vehicles may be possible inside of the building. The applicant has indicated that there would be only one additional employee beside himself and does not anticipate any additional staff at this time. If any additional staff is added in the future, staff will review the parking requirements and discuss the options with applicant for any additional off-street parking. The Zoning Code requires a minimum lot size of 40,000 square feet and lot width of 150 feet within the I-I (Light Industrial) zoning district; the applicant's lot size is 22,233 square feet and has a lot width of 60 feet. The applicant also owns the adjacent lot to the west (18,725 square feet and 60 foot width), but would prefer to allow that lot to remain open for possible resale for future . . . commercial use. The minimum lot size within either the B-2 (General Business) or even the B-3 (Heavy Business) districts is 5,000 square feet. Minimum setback requirements within the 1-1 zoning district are 50 feet in the front yard and 25 feet along both the sides and rear. Because of the required setbacks within the 1-1 zone, the subject lot is virtually unbuildable by itself. The applicant is proposing to encroach 40 feet within the required front yard setback, encroach 9 feet along the east property line and encroach 21 feet along the west property line. As indicated before, the applicant may need to adjust the site plan in order to allow for an off-street parking stall that will need to be located entirely on the property, thus pushing the building back on the property. The applicant is proposing a metal clad building with brick accent along the bottom third of the office area. An asphalt shingled overhang is proposed over the office door, asphalt shingles are also proposed on the roof. Staff would encourage that the applicant consider alternative building materials (i.e. brick, decorative block or stucco), especially for the front fayade of the office, other than the proposed steel siding shown for the storage area. The Board of Adjustment may consider approval of variances based on the following requirements being met. 1) Strict enforcement of the Title would result in undue hardship with respect to the property: The current zoning requirements for lot size, width and setbacks within the 1-1 (Light Industrial) district would result in an unbuildable parcel. 2) Such unnecessary hardship results of circumstances unique to the property: The property was platted as part of the original town center with a 60-foot lot width, the lot is long and narrow with a lot area of 22,233 square feet. 3) The hardship is caused by provisions of this Title and is not the result of actions of persons presently having an interest in the property. The 1-1 zoning requires a 50-loot .front yard setback and 25-100t side and rear yard setback; a minimum lot size of 40, 000 square feet and minimum lot width of 150-leet. The property size and dimensions were not a result of the applicant. 4) The variance observes the spirit and intent of this Title, produces substantial justice and is not contrary to the public interest. The variances would allow the property to be buildable for a commercial use, which the property is guidedfor within the 2020 Comprehensive Plan. The variance is not contrary to the public interest. 5) The variance does not permit a lower degree of flood protection. . . . Although the property does contain flood plain, the applicant is staying well away from the flood plain boundary and does not anticipate the need to do any filling of the .flood plain. RECOMMENDATION Staff recommends the Planning Commission approve the variance application for the following: 1. Permit a 40- foot encroachment into the front yard setback; 2. Permit a 21-foot encroachment into the west side yard setback; 3. Permit a 9- foot encroachment into the east side yard setback; 4. Allow construction on a lot less than the required minimum lot size of 40,000 square feet and minimum lot width of ISO-feet. Contingent upon the following: 1. The applicant current the site plan if off-street parking is planned, not utilizing any of the City boulevard; 2. The applicant place additional screening along the east property where vegetation or fencing is not existing; 3. The applicant considers design changes to the front fa9ade of the building to include brick, decorative block or stucco. ;;~u:~..?- Michael Schultz Associate Planner cc: Bill Sauber . . . 1 CITY OF FARMINGTON VARIANCE APPLICATION Farmington, MN 55024 651-463-7111 FAX 651-463-1611 Applicant Name 5.... .. O,eA.. ". ~ '1 .k'~ G- Applicant Address 100 '3 &...1) -;..,.. ra.-:-o ;..,.;-&- Street City Phone Number (, <!j' ! - ij b 'J - , q ~ 'I Legal Description of Subject Property: (104 block, plat nam~, section, township, range) ~ 3 ~ '3 I ~ ~ ';-0 "~7~ For office use Pennit Number "'JnAL State ~"'d" t.f Zip Code Current Land Use ~ Current Zoning District I - I Following Attached: (please check) _ Proof of Ownership _ BoundarylLot Survey -1C Application fee ($150) ~ Copies of Site Plan _ AbstractlResident List (adjoining property owners only) _ Torrens (Owner's Dublicate Certificate of Title Required) Property Owner's Signature 4#~ Date It:) -4 - 00 For office use only . Request Submitted to the Planning Commission on /0 - ~ - 00 Public Hearing Set for: It) ,- ;)" -00 Advertised in Local Newspaper: /CJ - /2- - 00 Planning Commission Action: Comments: _ Approved _ Denied Conditions Set: Planning Coordinator: Date: . c o .- +-I CO (.) o ..J ~ +-I '- .~ o '- a.. '- (J) ..c :::J CO en . o en "'0 o o LL "'0 o Ol ';:: ca ~ o o o 00 .is H.iv ..- o -I Dr~.~ ca a> :r:en ~oo u- ,_ :::J 0<( c en ca c E a> I e 13 <.9~ en :2 Q) 0. E. z ~ >- E a> ~E cb 0 Ol:r: c U5 I- 00 W Z a.. 0.. o .J:; en o - :::J <( C o en L- a> "'0 a> a.. >- .- Ol E c ca.- _ "'0 I == +':::J :::JID ~ .is a ~.".-- ,:~.}t:I.. .~' 'to' . 1) J> Z . M IJ Q ,- q . / S m ~ \) Q LOT 3 BLO K31 LOT 4 60.05' , i ~. r~---~- I I I I I I I I I I' I I I I I I I I I I I I I I I I I I I I I I 1'; HI q S &'1055' t'l PINE STREET Ib'-o" I I I I I I I I . I I I I I I !O _ ___..J ~ IQ:"~ ... . \~ . I~A:' lJj};1j '!..~....:..";.i"'P 60.05' Di~ro.M .;\: I Dr1ll;:..1 c;rk ~l"",, ".: -;...~~ . ',,,- :/ l:'-~ . . . IV {) q . ~ tt ~ ~ LOT 4 LOT 3 BLO K 31 60.05' Cu." r"':---~- -----, I I I I I I 16'-0' o \:) ,~r-t.W. k Ac..~ ~~~~ \1..... Lo~.~ ~ 2 ~ ' a. " r. - -.... It' A~ "",LJJ,..t., _ ..L -...1. ./ n'-'1'W4X- ~ ~ Q Jr, ~ f-,. j~1: "-'o~~)' .. ~/d~7 ~q.~.. .'~/;~p S e<lc:lSS' I'l , PINE STREET 60,05' .,!:.. , .~ ~i~ ~~ . ,.~ ~~.,. . . , M IV Q .- q . ~ ~ ~ .~ LOT 4 D~~,..-", -#- 3 ~DS1~~~ ~u~J s't~ ~aA :\ ti~ "";lA; ~ ~ ~l",..c.~ J LOT :3 BLO K 31 00,05' .'~8 , ~. a. 16'-C' I I I I I I , I , I . I I , I , I . I I I I ,I I 10 -----.,J ~UI-L- Fto^~ ~ror . ~ ' I 2"5 I g oui~ ()WJ.. I t: PINE STREET ~. ,;r . .'1i,\ '. ~. . . 10-4-2 W ...l CD ~ '" ... Z ::l c:l'w ~cr ..I(.J ...l< Wcr ~w aeL '" '" o cr c:l ~I II 2 ~ ::l...< 20cr X..Iw < > 2 0 (.J '" W ...lcr ...l::l <... u.(.J O~ ... '" ~Io - '" '" ..,; ~ :.: (.J < ~ !:ilo w w'" '" cr a cr < >- ~Io ~ '" u. w ~~o N 2t ~ U3~ ... 9 2 ::l 2 Z 2 <t~ .. w . ~d ! u '" u.. =2 :! c. -3. .- .. :::l cr- . '.c .0 3 '3 .!:! a. < - .( '" .., '" co; ~ '" '" o ,..; '" on it o <') '" 0 cO ,..,: ~ '" .., on ~~~~t/. ;;f 1.1)0000 0 NMM(\IM ('"') o '" CDa)2g2 U>>CG222 2~2g2 UlUlUI!~g 2 o <'II fGUle~~ cof02~S ~S2g2 cGq)"'S!~g ~ o '" 00000 00000 00000 000000 0 NNNNN NNNNN NNNN(\I NNNC\aNN \I) a '" - "''''00''' 0"'00'" "''''000 000000 '" ,....OI~~Cft <<0""'00"-" ""'''2COf.D COcaUl~~ca ..... . . .- _ u ~.. o -.., it '" <'II 88!88 88888 88888 888888 8 ~~1'i~~~ ~~~~~ ~~~~.~ ~~~~~~ ~ --ir("')- -NN- ----- _NN_ "" := !i~~~: U.Eo!i" i~J:u.~ ~oi~~ ~.!~20 ~ c . :2: ... ~::l ~j ~ ~ 0- '. . c : . It a ~ at 0 < ...l <'II .( - Ii: ~ e .. u. .!! >-.:~. at: ~'e. .5 Eo.... ~~~~~ ""o~=~ '~.!~:i5 . a ,; . 2 '" Ii: ~ 'e .. u. .!! ,..:~. g''E ae S Cij~J:~::l I , c...:.;; ""o~'5J: 'j ~ 0 20- c...... . a .c at J: <') Ii: City of Fa.rmington ~ .. . . S .. u ::l .!!~ <( ee~~~. .....eoE: 2~"J:~~ . . Ii. c: . ... Ir; ~~5 8"'......20 ~ . " 2 .., Ii: ~ . Q. Q. .. ,!:! ~~. . . ~~: : . '>.u.. :J c :"i~:; 'ii c'U ~= .s .~w20 j CD e g ;:jc:l '" cD cD 0'" "'''' 00 "'''' it '" '" it ~ '" '" <')<') OOCta:t-nI.tJU1 '" '" '" 2~O Q) ~ ~ ~ g~o 0 ~ ~ ~ 000 0 0 0 0 III"'''' III I.tJ Q 0 - '" '" 080 S! 0 8 0 808 CS g 0 g .Ii.D"'. tIJ" 0 0 0 .., CD CD . . ~ : : ~ ~ ~ .. <( . ~ ~ c 'Ci .. .2 i -6 ~ '" c . > - .. · J:. a ~ 2' (.J <')...l cD - U 10-4-2 ~ CD ~ M ai '" ~ .,. CD o 'C o i:? CD <>> - .,. ..,. o C') ~ CD o '" ~ ~ ~ 0 w ::I w cr :5 00 ~ '" ... N <.) CD 1C '" ... N '" CD Q 0 ~ 0 ,; < 0 0'" 2'" 1C _ a.. CD ~ M a u, ~ ,..: 2 0 ~ cr 0 w 0 _ ... 0 CD ~ CD 0 ,; o '" '" C\I C!l ~ - - ,; .. E : to ::l iJ:i .. <( ~ . - .. .. c : :l.; N ::l <( ii: - ~ .. '8 rD ;...~~ ~ tu:'! cD ~ ~ . CD o 0 c 0 ~~~ ,; -' '" <') 0 ~ u:. t.L ~ * 594 . City of Farmington 325 Oak Street, Farmington, MN 55024 (651) 463-7111 Fax (651) 463-2591 www.ci.farminilon.mn.us TO: City Planning Commission Michael Schultz ti-D Associate Planner FROM: SUBJECT: Variance Application - Lot Coverage and Loading Dock Access off Public Street DATE: October 24, 2000 INTRODUCTION The applicant, JIT Powder Coating Co., 21020 Eaton Ave, is seeking Planning Commission approval on a variance application to exceed the 35% maximum lot coverage for buildings and allow for a dock loading ai'ea fronting Eaton Ave. . Planning Division Review Applicant: JIT Powder Coating Co. Timothy Milner 21020 Eaton Ave. Farmington, MN 55024 Attachments: 1. Application 2. Location Map 3. Site Diagram 4. Section 10-4-2 5. Section 10-6-22 (C) 6 Location of Property: 21020 Eaton Ave. Legal Description: Lot 2, Block 1 Farmington Industrial Park 2nd Addition Lot Area: 183,803 square feet . Surrounding Land Uses: Industrial Land Uses surround the property . . . Current Land Use: The proposed expansion is occurring on an existing vacant industrial lot Existing Zoning: I -1 (Light Industrial) Comprehensive Plan: Light Industrial DISCUSSION The applicant, nT Powder Coating Co., is seeking two variances in order to construct a 40,000 + square foot addition to the north of their existing building. The first variance request is exceed the maximum 35% lot coverage by an additional 5% to 40% lot coverage. The second variance request is to locate an additional docking area facing Eaton Ave. (see attached Section 10-6-22 (C) 6). The applicant is seeking the variance to exceed maximum lot coverage in order to construct the size building needed for a new paint line that requires a certain length for the whole process to perform as needed. In a letter sent by the applicant's architects, the length of the paint line created the need for additional square footage, the line could only be constructed running north and south due to the length required for set-up. The applicant's second variance request is to construct additional overhead dock doors facing Eaton Ave. In the City's Industrial Overlay Ordinance, it requires that "loading docks shall not be permitted along the street side of a building. The design of the loading docks shall be incorporated into the overall design theme of the building and constructed of materials equal to or the same as the principal building." nT Powder Coating currently has four existing docking doors facing Eaton Ave, the building at that point is setback 65-feet from the property line; the building is setback at the minimum 25-feet from the easterly property line. Because this property is a corner lot (Eaton Ave and 208th Street) and because the existing building is at the minimum side yard setback (25'), there is no feasible way to locate the dock doors on either the south or east facing walls. The Board of Adjustment may consider approval of variances based on the following requirements being met. 1) Strict enforcement of the Title would result in undue hardship with respect to the property: The current zoning requirements/or lot coverage within the 1-1 (Light Industrial) district would result in a limited expansion, limiting the overall potential use 0/ the site. 2) Such unnecessary hardship results of circumstances unique to the property: . . . Staff feels the lots that were platted, especially along the east side of Eaton Ave and the west side of Edmonton Ave, were not created deep enough to allow for the turning radiuses needed for full length semi-trucks. 3) The hardship is caused by provisions of this Title and is not the result of actions of persons presently having an interest in the property. The Zoning Code restricts maximum lot coverage to 35% in the 1-1 (Light Industrial) district. The existing location of the building along the east setback prohibits the space for loading docks and the turning radius needed for full-length semi-trucks. 4) The variance observes the spirit and intent of this Title, produces substantial justice and is not contrary to the public interest. The variances would allow the applicant to expand their existing facility to incorporate a new paint line; the variance would not be contrary to the public interest 5) The variance does not permit a lower degree of flood protection. The variance would not effect any flood protection. RECOMMENDATION Staff recommends approval of the variances to exceed the maximum lot coverage an additional 5%, from the maximum 35% to 40%; also to allow the applicant to front the proposed loading docks toward Eaton Ave due to limited space along both the south and east sides of the property contingent upon the following: 1. The applicant add additional landscaping along the north and south sides of both the proposed and existing dock areas; Cc: Tim Milner, TIT Powder Coating Co. Brian W. Houwman, AlA, Houwman Architects . . . CITY OF FARMINGTON VARIANCE APPLICATION Farmington, MN 55024 651-463-7111 FAX 651-463-1611 For office use Permit Number Applicant Name ::::r;1 Ye>u.fD ~ Applicant Address ~ ! O~ 0 Street Phone Number tc S 1- '-I {jj 3 - 4 (pI.,;, L/ Legal Description of Subject Property: (lot, block, plat name, section, township, range) 550"2... Zip Code Current Land Use Current Zoning District Following Attached: (please check) _ Proof of Ownership _ BoundarylLot Survey ./Application fee ($150) _ Copies of Site Plan _ AbstractIResident List (adjoining property owners only) ~ _ Torrens (Owner's Dublicate Certificate of Title Required) Property Owner's Signature ~~ o-#', .4. ~. . Date 6_~ 00 . For office use only Request Submitted to the Planning Commission on Public Hearing Set for: Advertised in Local Newspaper: Planning Commission Action: Comments: _ Approved _ Denied Conditions Set: Planning Coordinator: Date: -- ~20-2000 7:54AM / FROM HOUWMAN ARCHITECTS 639 9726 P.2 . ~ 10...11 AHCHIHW [~~1H3iliiTfU mm SUUTH wESI~riE"iv8RiG""TOK. 'MK 5'S 112 () , .,..- --.. ,.... ..;----'I:,:;~..;-l]lLIE~j"?oQ~~~.....~J : 1.1. t..6~..I.J3J...mS.. ,.. October 20, 2000 Mr. Dave L. Olson City of Fannington 325 Oak Street Fannington, MN 55024 Re: JIT Powder Coatings Dear Dave: I am writing to yClU today regarding JIT Powder Coatings building expansion project. The building expansion is designed to expand towards the north with new access to the site from the north off of 208th street. The Owner is requesting approval from the city for two (2) variances for this project which arc explained below. . The first variance is for additional square feet to be allowed in addition to the exi~ting 35% coverage role. For example, the site is now going to be 183,803 SF, We are now allowed 35% lot coverage for the building's footprint; this calculate.c; the lot coverage to be 64,332 SF. Our new total building footprint (including the existing building and it'~ new addition) is 73,925 SF., which would mean we would need a variance granted for the additional 9,593 SF that required for our addition. The reason for the extra square footage is becausr.: the paint line requires a certain length in order for the process to work. That length created the additional need for the square footage because this line can only work in the north I south direction causing this extra length which thL't) created the additional square footage. i i A. I The second request is for overhead dock doors being able to face Eaton Avenue. We are asking for this variance to have these dock doors face the street because the building expansion is adding Onto the exiMing dock area of the building and the current existing dock fdCCS Eaton A.venue. These n~ dock$; need to he adjacent to the existing docks in order to keep the loading dock operation of the building together. This allows the building and it's tenant the best production flow. If you have any questions or need to di~cuss this request further, please call me at your convenience. Thank you. Sincerely, 6AJ11JA.1J. t Brian W. Houwman, A.I.A. Mn License # 22604 Prcsident- HCluwmun Architects, Inc. . cc: Owner BWHlcdp .-...._.__4.. . ,.. .. ._..~ .M..... M....M_____._ .._.____..1 . c o .- '+-' CO o o ...J .~ Q) a. o L- a... J- - J . ~\:7" UJ ..' ~ -- >- t Q) c.. 0 L- a.. - u Q) ~~\ I i ~'\ )< 1 3^V NOIV3 [ 3: f- CI) I f- CO 0 - N 10 La ~---- NOl.NOVII03 I . 3^V J~=- ~r~ cr: I . r (~ I/' ---------- ----n r::= -, ~ -------- ---- PILOT KNOB RD (CSAH 31) - ~ ------ -- -~--- 208th STREET . ..,~~ .-.c/r- ~~~'Ze5' o Lo ~~---~-f--!(;1:'<?- P....RKIN6> $ETe...~. -- C9l -=-,- -\ I .~.J ~: \ I i: 'I =r1 I '-_.J - \ , I . I i I :0' .~.".il~! 0' ~..,,,If __I, '(P) I" I o I , 101 I I 1 I 101 I , lot I : 101 I , 0\ I I ".~.I flJIt..D1Ne> ~'T I I \ II ~~ I I I, ~~r;,;; I. 5TR~ 19 SHe J. F~'" PERIl'" pROI\" ..oq 10 . ex'." I '"""~ $~ ~AI!l flYf' o , , '" ""' --.c ~:!t @~~~<?SED SITE PLAN 'i . . ., f\J : -I ~T rn r-- In / ""- )> I () Z . . n;m 4 . I /" - . ~ ~ o ~ ~~ ~ li- - ~ ~ : _.1 I~ I ~ m.:;:- F~ ~ IT] <V' IT] , )>;- --\ () z ~ J ! ~ . o ~ \ -f1~~ ~ ~It.! l ~ ~ -i j=~l i - ~ ? r ~a ~~ ~. i~ h ~ - j- ~ -H q ~ -- d l ~' _ z ~~ ~ ii ~ ~! lIJ [CI IT] ,,!~ ~~17-2000 2:18PM / / . FROM HOUWMAN ARCHITECTS 639 9726 P.2 r- I \ I I I I I I : I I I , I I I I I I I i I I I I I ! I I I \ 0 : I I I -----___ : I ~ It I 'I . I :, , :~ '. . . .;.." I I 1I......~........====t=:=====:======= -.: : I \ I I I , i I rl : I ~ I I I . I : I ! I !I : \ ~ !:f'~7'I: ~ ! 'i~;'! I !:~cr~: 00 ,L_________________ _ I . I-- I I I I I I -----,- I I I I I --,- I I I I I I I I I l I I \ I I \ I I I , I a . . u u . tl" .... .. '. '. 10 . ,. '..' ", " . . , ..... .' ,-: " .~ .: ~ " . ' o I I L-~_____________________1_____________________________________ ---'~~"'''''-'-'-~''''.''-~"''''':'''''''''-J~'''~~_~~'~~,~~__~_._..~,~1'''~." . ..t............ "'..,.,.:----..1-'_..,....."...._~..;o _ 0-''''''3" -,.,- ~_,"T;\.'!P~~.1,.r:c. ~;'_.~ ,_.<.."'T'lI'_~~_~3"':-~: . ';:;!;:;!~zCl #vv)>\)1t f"\-l-IiOCI1 ~)>)>mU'l(\ IIrr:t:-Im m U'I U'I Clc ~ I 3:-1-1 )> \l)>)>M1r.::::: rll tv o II I 10 -<'U'lU'I-.:::::Cl m~~~8~ ~ldO . U\Z~O~II r1mU'l:-nUt m-f>..\)'1t.). U'I Ul . -f>.. U'lU'IIIIZu> -1-1(5'(5')>1:3 $ ~ () _Ul Cl ZIU'I~ () IU~~O 11 m V' I ........ tv 0=irtv cmU'lCl 0> 1U:t: () U'I m)> 0 -I QU'I II ~ ('\U'I Ul I ()Il tv U'I 2~ U'I :4rn -I )> 11 r Cl r iO U'I iO rn ld c iO rn G Z c :! OJ rn iO Cl 11 Ul -l )> I I U'I . 1) )> "j{} 7\ z G\ "j{} rn k> c iU rn :r rn z -t U\ OJ OJ OJ OJ ()-I rrrr \) \J \J \J -I)> ~~~~r fI>~('\('\1 00f"\ )>)><<v U'lUl -l ll\JrnrnU'l I:t:iOiO'1t )>)>)>)>. rr<i'<i'1I -I-Irnrn 1l\J\JIlO> j{JmiOrnUl O~O~~ 1l~1l~0 Cl=iO::::jUl U'I -l U'I -l '1\ m rn rn rn :-" \)\J\J\J:-n U\ -t rn z () -t rn U\ G\ m z m Al )> r z () -1\ m lJ) II II II II =(5'-10) tv\J1tvUl ).~"".1\ ~ .11101 - 0 ~::fiU'l(5' :1l~'1t-f>.. -1' 1Jl IV<~ ~)>U'I :-n~'11 )>. Z ('\ rn iO rn ld c -+ ~-C:. GO 11~ o iO 0> \J1 \1' ()> U'I II '- "t ~\~~ w '10 C> \1', -~ -:....s, ~ ~ ~ ~ C> o ~~.L ~ ~ r ~"'..-o ~o .\11 c.t~ . I I ~ u~n tr:l ~== I ~ ~ Qq~;e~ J.;:J c::::t > ~~~ Z ~~'T1....l r:' 9rv.. - '1 . ves "0 ~Z;~ !i C)"" CD 0" is" o ::l 0 0 (X) CD Q. C. ~ !.~l .... ~~'-c g F. III ~ -- ~ ~ ~ ~ 5" ~ : -- III = ~. 51! c: co III .. III 3 ~ . o a. o ...li; CQ O-i -- C m N g ~ ~ Z m 0) c ~ ~ cO 'tI -- :Jl o I\) f ... 0 > ~ 0 ~ o c CQ c;; I\) -i N :Jl CQ n ~ '" ~ :: 0 ~ c Ji m ~ m Z -i ~ '" ':' - ~ c;C::t g ~ : = 5' ~ ~ ~ ~ =-. ~ . g -< i .. ~ ~.. ~ 5= ~ : : 5= III .. II> II> ... o c 0 (It U\UlU\ ;:, .0 ;:, ;:, 888 g g g g 000 I\) I\) - OOCl\CIl'"Ut'" o 0 0 0 000 III o~!!!i_ gf=i"i tD -.... Cift ~':".c. ..~3:' : :; ~ oc~ fj' III '0 '0 III ~ g g g 0 o~~ N cO I\) o !i o CQ Co) ~ o . ~ ~ ~ ~ ceo . __ I\) CQ '" cO !--? o !i o CQ . ~ I\) lZl Cf --.j cO ~ ~! ~ C)r- ~ ~ ~: ;c- i z. III O!l:-i-i"'& ; i"i:~~~'. 5" ....7.=~.. : C~::tID.,,!II: .. :303..1D >= ..~:~~g ..e. n ~ i ~ c: .. III .. UO~U?U.l.lf).i }o An;) :Jl r:. ::t Ci ::r C III Q!l:c;t~~ ::rs.lEooc !~=.;,~ C:1Dg:~5 lG 3 C --Cl .~:~Cf " ID ~- ~ :Jl N !II: .. ~ c .. O!ll:-i-i5 S-s.i~~ ! 0:-=';" c:~::tID'" : ~ g g,~ "~:ociD ." ID ~ ~ ~ ~ lE C III ::l !!, .:c Qfc;t~~ iE~9~ ..... -n- c:;:'::t;~ :..~~=;:' ~..oc ~_ ~ o ::~~::mCD c;;;; :::~pj::o .;~;tL~~ C 00'00'02 coobb "ceo.oc ccn:rco g gggggc; ggggg ggggg ggigg ...., o>OOCJ)G)CJ) Cl>CbO...,...., ...,co.....'" CiU'lU\CD-...t UI 000000 CCCUIUI UlCCUlO UlCCUIUI U\ 1\)f\)f\)NI\lN f\)1\)f\)1\)1\) NNNN~ NNNI\)t\,) C cooccc CCCCC CCCCC CCCCC C 0000)(1)0 00000 C;CCI)G) ooomo>> ~ ~ ~ Ch 000 ; OOOCf)CftCl) 00000 C;COCl>CD CCCCDCb . G-p.Q ~ '" '" UI UI ~ If. I\) UI If. I\) '" ~ I\)1l> 00 Nil> "'0 ~ WNWWI\) o 0000'" ~ ;1.f!.#-f!.~ '" u. " o ... o ... N '" C If. '" '" " o I\) '" ~ '" u. ... u. > ~ N - > > Cl '5! 'tI .r i 5. :: c Q< Q!. i. :r. "'" I !:II c:~ c:: ::~. .. a .: :! ::l .., ... .. !!. - ...- CID IDn ~i .. .. o;~ ID n "'> ~ i P:Jl !II: .. "m Z -i> f c: !II: 5 -i ~~~ ~ - UI C '" C "'I~ cO Z -i I\) o NI~ C > :Jl N C NIl!? o c m (I) -i :Jlo ~" -i> c:r- :Jlr- m (I) Ii Ig . , -i > III r- m -< > :Jl C (I) m -i III ~ ~ ':n ~ o !II: o > <r-x mo- ~-i~ ~ !II: C) :Jl o (I) (I) 'tic m~ :Jlm >r- Or- ~z C) c: z ::j (I) ," , ..- G-p.Q ~ 1 0-6-22 . * . (D) (E) (F) . 10-6-22 roof edge or an opaque screen constructed of the same material as the building's primary vertical exposed exterior finish. Equipment shall be painted a neutral color. The site plan shall indicate all mechanical rooftop equipment and shall include elevations. 6. Loading Docks: Loading docks shall not be permitted along the street side of a building. The design of the loading docks shall be incorporated into the overall design theme of the building and constructed of materials equal to or the same as the principal building. The loading dock areas shall be landscaped and/or screened so that the visual and acoustic impacts of their function is fully contained and out of view of adjacent properties and public streets. The architectural design shall be continuous and uninterrupted by ladders, towers, fences, and equipment. Businesses that abut County Highway 50 and/or County Highway 31 shall not construct loading docks that front these roadways. 7. Trash Containers: Trash containers or trash compactors shall not be located within twenty feet (20') of any street, sidewalk or internal pedestrianway and shall be screened by a six foot (6') masonry wall on three (3) sides of the trash unit. 8. Coverage: Unless otherwise approved by the City, the ratio of building square footage and parking area shall not exceed sixty five percent (65%) of the total square footage of any building site within the affected property. Utilities: All buildings and structures shall be served by underground utility distribution facilities. The installation of such utilities shall not change the grade or contour of the City-approved grading plan for the site. Building Setbacks: No building or other structure shall be erected within fifty feet (50') of the front property line; or twenty five feet (25') of the side and rear property lines. If two (2) or more lots are developed as one site, the interior common lot line shall be ignored. Parking Areas: 1. Surfacing: Prior to issuance of a certificate of occupancy, all parking areas, driveways and loading areas shall be surfaced with asphalt or concrete pavement following the City's Engineering Standard Plates. In the event said surfacing cannot be completed due to weather or seasonal restrictions, a temporary certificate of occupancy may be issued contingent upon the extension of the 398 City of Farmington 1 0.6.22 10.6.22 (a) Brick: Size, type, texture, color and placement shall be approved. . (b) Stone: Stone shall have a weathered face or shall be polished, fluted or broken face. (c) Concrete Masonry Block: Concrete masonry block shall be those generally described as "Customized Architectural Concrete Masonry Units" or shall be broken faced brick-type units with marble aggregate. All concrete masonry units shall be coated with a City- approved coating. There shall be no exposed concrete block on the exterior of any building unless approved by the City. (d) Concrete: Concrete may be poured in place, tilt-up or precast; and shall be finished in stone, textured or coated, with a minimum life expectancy of ten (10) years. 2. Alternate Materials: Alternate exterior surface materials of preengineered metal may be substituted in an amount not to exceed six percent (6%) of the exterior wall surface area of each building if the following conditions apply: (a) Used for housing or screening equipment necessary to the manufacturing operations; . (b) Architecturally compatible with the building as a whole as determined by the City Planning Division; (c) Compliance with any additional screening and/or landscaping requirements of the City; and (d) Modifications are made with prior written approval of the City Planning Division. 3. Alterations To Buildings: Any alterations to buildings shall meet all requirements of this Chapter. 4. Canopies: Canopies with visible wall hangers shall not be permitted. Design of canopies shall be in keeping with the design of the building and shall be approved by the City prior to construction or alteration. , 5. Roof-Mounted Equipment: All rooftop equipment shall be set back a minimum of twenty feet (20') from the edge of the roof and shall be screened. Screening shall consist of either a parapet wall along the . 398 City of Farmington . City of Farmington 325 Oak Street, Farmington, MN 55024 (651) 463.7111 Fax (651) 463.2591 www.ci.farmin~on.mn.us TO: . City Planning Commission <J9 Lee Smick, AlCP Planning Coordinator FROM: SUBJECT: Petition to Rezone A-2 (Agricultural Preserve) to R-l (Low Density Residential) - Donnelly Property DATE: October 24, 2000 INTRODUCTION Farmington School District #192 has entered into an agreement to purchase 60 acres from Robert Donnelly, Jr. between 190th Street and 195th Street adjacent to Troyhills. The property is currently in the Agricultural Preserve District and is zoned A-2. The Donnelly's are seeking to rezone the property to R-I (Low Density District) to allow for a proposed elementary school directly south of I 90th Street. . . Plan nine Department Review Applicant: Robert Donnelly, Jr. 20080 Flagstaff Avenue Farmington, MN 55024 Developer: Independent School District # 192 51 0 Walnut Street . Farmington, MN 55044 Attachments: I. Rezone Application 2. Zoning Map 3. Comprehensive Plan 4. Conceptual Site Layout 5. Conditional and Permitted Uses Rezonine Requirements Location of Property: The property is located south of I 90th Street, west of the Troyhills subdivision and north of 195th Street. Size of Property: 60 total acres Area Bounded By: Agricultural land surrounds the property on the north, west and south. One single-family home exists on the south side of 195th Street. Single-family residential . . . . abuts the property on the east III the Troyhills development. Existing Zoning: A-2 Agricultural District Current Land Use: Agriculture Comprehensive Plan: Low Density Residential Proposed Rezone: The owner seeks to rezone the property from A-2 (Agricultural Preserve District) to R-I (Low Density Residential District). Proposed Development: The developer proposes to construct an elementary school on the property within an R-I zone. A Conditional Use is required for the school within an R-I zone and will be applied for at a later date. Streets and Accesses: The developer proposes to utilize 190th Street as the primary access to the new elementary school site. Currently, 190th Street terminates at Everest Path therefore; the developer will be required to connect 190th Street to the west for access to the site. Everglade Path and 193rd Street are also identified as potential accesses to the site. Water & Sewer: Water and sewer access is available within the Troyhills development until a trunk sewer facility is constructed west of Troyhills. . Topography: Site topography is generally flat adjacent to Troyhills and falls to a ravine that runs north/south on the western portion of the 60 acres. Wetland: No wetlands exist on the site, however, the City's Wetland and Waterbody Classification Map identifies the existing ravine as a greenway corridor. Flood Plain: The ravine is identified on the Zoning Map as F-3 (General Floodplain). Parkland and Trails: The developer proposes to connect with existing trails in the Troyhills development that run north/south along Everest Path and east/west along 193rd Street. A tot lot exists at the southeast intersection of Evens ton Drive and Everest Path. Park requirements by the school district will be met through the required playgrounds and ballfields on the site. . . . DISCUSSION Mr. Donnelly is requesting to rezone 60 acres of his property from A-2 (Agricultural Preserve District) to R-l (Low Density Residential District). The 2020 Comprehensive Plan (see attached) shows the western portion of the site as natural open space and the remainder of the property as low density residential. The proposed rezone from A-2 to R-l complies with the 2020 Comprehensive Plan; therefore no plan amendment is required. Since the property is within the Agricultural Preserve program, the School Board has recently sought to remove the parcel from this status through an eminent domain acquisition process. This process includes a Notice of Intent to the Environmental Quality Board (EQB) for eminent domain action as provided in the Minnesota Rules Chapter 473H.15, Sub.2. This request was reviewed at the September 21, 2000 EQB meeting where action was not taken on the item. However, due to the before-mentioned state statute, the eminent domain proceeding was eventually approved because the 30-day time period for voting against the action had expired. The attached conceptual site plan illustrates a building footprint, accesses to the site and play areas. The proposed use requires a Conditional Use Permit in an R-l zone; therefore, the conceptual plan may be revised upon detailed review of the site by ISD #192 and City staff. The proposed school will be located in the general vicinity of the building footprint as shown on the plan. Therefore, the proposed school will be situated directly to the south of 190th Street, which requires 190th Street to be extended to the west from the current termination point at Everest Path. Additionally, the school district proposes to separate the bus traffic from general traffic with two separate accesses. A third access is shown on the conceptual plan at Everglade Path; however, upon review of traffic requirements by Shelly Johnson (see attached) and City staff, Everglade Path may be utilized as a trail to the proposed school rather than a vehicle access. The remainder of the property to the south is shown as play areas and open space. 193rd Street is shown on the conceptual plan as terminating at the eastern property line of the Donnelly property. The 2020 Thoroughfare Plan identifies 193rd Street as connecting to 1951h Street to the south through the Donnelly property. This connection will be required to extend through the property when the southern half of the property is developed. 190'h Street is shown as a future collector eventually intersecting with Flagstaff to the west. 195th Street is shown as a future minor arterial expanding to the west as well. ACTION REOUESTED Consider approval of the petition to rezone of the Donnelly property as described on the attached legal description from A-2 (Agricultural Preserve District) to R-l (Low Density Residential) District) bringing the property into compliance with the 2020 Comprehensive Plan, require a Conditional Use Permit for a school use within an R-l District and forward the recommendations to the City Council. .~~ Lee Smick, AICP Planning Coordinator cc: Superintendent Greg OhI, ISD #192 Philip Behrend, A TS&R . . . . i., . 19/12/00 THO 10:14 FAX 651 463 1611 CITY OF FARMINGTON IaI 00 ~IJ. . If Q;lrh. I ~ II~III~ m i ~ I III ul ul ! ~ ~ ~~ l~ ~~ ~ t i ; Ii h~i · I u.. NW 'NoJ.!>Nr.nIv~ L6L 'ON .1:lClUSK! 1OOI-OS ~ A}lV lN3W313 NOIQNIWW:J M3N 3Hl 1ML l- e.. UJ U Z o U . . . PETITION FOR REZONIJ\1- I, the undersigned, am the fee O\\11er of and hereby request that the following described land: F\,,)~(e Sc..~~ol (EI~W\,,~~,'( Sf. ~ol IS,", il IJ j'j) '~J+~. Se ~ (~..:~:t..~tO J) esc.rYJ 'h'olA_ be rezoned from: A - ~ to: "R" ... I I understand that a public hearing is required, as well as a published notice of hearing, for which I hereby attach payment of the fee in the amount of S '3 00. ~ , which I understand further will be refunded if no meeting is scheduled. &Jb~~ Signature B6~ L).-~( r: ~-~G,-VO Date The Planning Comlnission recommended on the to (approve) (deny) the petition. day of ,19_ City Planner Action of the City Council: 1. On the day of ,19_ declined to set a Public Hearing. 2. At a Public Hearing held the (approved) (denied) the petition. day of ,19_, Date City Administrator In accordance with Title 10, Chapters 2 and 12 of the City Code. cc: Planning Commission, Council, Attorney, Engineer, Water Board: P ARAC /- . . . PURCHASEAGREE~NT This Purchase Agreement is made and entered into this a~ day of August, 2000 by' and between ROBERT J. DONNELLY, JR., a single person, and BRIAN J. DONNELL Y and KAREN M. DONNEW, husband and wife, hereinafter referred to as . "SEL~" and INDEPENDENT SCHOOL DISTRIcr #192, hereinafter referred to as "B~" on the following terms and conditions, to-wit: 1. DESCRIPTION OF PROPERTY: The propertY being sold hereunder is located at: Street address: 19224 Flagstaff Avenue City ofFarmingtOD, Calmty of Dakota, state of Minnesota legally descnOed as follows: Approximately 60 acres of vacant land presently owned by SELLER and descn'bedas follows: That portion of the Northwest Quarter (NW~) of Section Twenty-Three (23), Township One Hundred Fourteen (114), Range Twenty (20), Dakota County, Minnesota, lying Easterly of the centerline of that certain creek that runs in a general North-South direction that runs through said Northwest Quarter (NW Y4) TOGETHER WIlli Outlot B Troyhill 3cd Addition, according to the duly recorded plat thereof: Dakota County, Minnesota The exact legal description of the property being sold hereunder shall be determined by the survey to be obtained as set forth at paragraph 15 below. including the following property, if any. located on said property: garden bulbs, plants, shrubs, and trees, all ofwhich property shall hereinafter be referred to as the "property." 2. SALES PRICE: The purchase price of the property shall be Thirty-Five Thousand Dollars ($35,000.00) times the actual number of acres of the property. For purposes of determining the purchase price~ the measurements set forth in the survey (as hereinafter defined) shall be conclusive and the area of the property shall be measured in a "gross" manner, to the exterior boundaries, and shall not exclude easemen~ rights of way, wetlands and the like. It is believed that the property consists of 60 acres and that therefure the total purchase price will be approximately Two Million One Hundred Thousand and 00/100 Dollars ($2,100,OOO.OO)~ The actual purchase price will be based upon the actual number of acres of the property as aforesaid. / doaDdly tobtpu~ . ~~ I ~ o i 115 J I ! ~ J ~~~ j I I!' i ~ I hi i; i ; M! ! ~ ~ I NW 'NO.mtM1JV:I l6l 'ON .J..:Jnl1SICJ 1O()HJS ~ i ~ a ~ . fI Ii: A~VIN3wm N019NIW~V::I I ~ M3N 3Hl i 8 ~ l; l!! }- I _<l: d)..J l; I . 16 INOl WA_AIN " "., 1~5T~ 5T . _ . I ....~:- ~~. _.....~,...._....<:....;--40,~>~~-;-;~~~~~:::::-.. ~.:..-~::. .':> :r-....1}..~._..~:.~ ---, II'.(~' ,,1,.-- , ',', '.', " \ " ',' , " , , ' , r , " .- - .- -',' I, 1/ I , \'1 ;, ; t I\'\' \.. ", .....'~" ~ \ \ I : j I! f /,' I J: ! I --"-', I ...... ; I " ! i\l . Iii' I ' )'" '," \ , ", \ \ \, "\ d \\ . " ,,!! \. I 'J ' -" I ,,( -'HlI ~I ~ . 1\ . \... ~. \ t 1 ~', Ii" ... ~ : I '. . \ I, ~.. . ..... . ~ I: \~ \ 'I'; \. \ \ \ \.. \\,~\\\\\h \. \\\ \, \\ \_':::~-'--- .,>..-.~~, ~ ~f \ ,I . l~. , . \ : '" ". .. .. ,... ,\ '.. \ "'. .' . r (j-' -' ~ t"n . I . .', .. '1"""\"',..\.""'-"'" (. ........, ~~ . J. I ." .... '. ':i\'.'.\'''' ,'\;, \...:,--',,',', ) j "r"", ". " I' '\" ' II " ,\.'~, ll" '';'\\\. ,,\\, ',-:-',:-.' ~ ,} ,! ...,j....., \ .~/-. 'T : ~ "....l '.," \' \ ,....\ \ \ \... ',,\~.,.'\...- -..... "", I.... / ." \\'" ...".\t.' I'" I "." ,I '. \ \\,~,,,,,,~\,,,,,"_-:---":'~,t-' /: I, \ I .~",.'. 'r 1\ ,,', \', '," .' ,'." ," ,"... ......,. '. 'j""' '.' : . I"' ," I u.. i I . I- :J fa 0 >-19 < -J ~. LU I- en I- 0- LU U Z 0 U . ro Q) < rf:1 - - .~ ...s::: S ~ ~ -- rf:1 ~ U .~ ~ rf:1 .~ Q bJ) ~ ~ N ~ o ~ gf .~ ~ ~ ~ o C .~ u . ~ fl ,," E i: E g- ] ~~~~5 ~ ~ ~ ~~~~u ~,,~ ~ ~ ~~;;S8e ~~~~ q j ~"g E Z co co ~ -E g ~ ~ 8 E c ~ ~ ~~ ",,, ":;,,,_C02">'''W::~::>-''-'' g ~ ~ ~ ~ ~ E ~.<: i: ~..E 0; -6 'E ~ Cl ~"8 ~<E~~5~~~~"8~~~gCl~~~ q~~~~~S~~8~~~~~~]~~ u :E Cl , ";' -;' ";' M ~ ~ ~ S.J ~ .3 ;:; -"- ,~~<<coco~i'_NM~Cl~~~:E <~lllllill'Di'D'li t.:.l z*m :s - Cll Cll L1.. o o o "<t o o o N --~- . . . l 2020 Comprehensive land Use Plan City of Farmington i I, ! 1f } ..._.~~ ..-.. 0.5 Scale o 0.5 1 Miles Legend . ,,\... City Boundary ~ J' MUSA Boundary 'r:nvironmentally Sensative. Flood Plain/Major WetlandsIWoodland r:=J Environmentally Sensitive within Developed Areas Environmentally Sensitive in Undeveloped Areas Comprehensive Land Uses r='1I Urban Reserve _ Business _ Industrial _ Business Park CI Low Density Residential r-l Low/Medium Density ... Medium Density _ High Density r"'III Public/Semi Public _ City Park/Open Space _ Restricted Development l--.J Natural Open Space [:=J ROW N W+E S ....,.~.. ", ,/ "".""..,<1- ''''''~'''''''''''''OII~ ___SCM.YOHl) MLolDtOI .l,ISl!D_fX.OeTOOV'--.... 0Iy~'..........."'--'Q~__...1'_ .-1 ! ! ! ! ! ! ! ! i ! ~.:._=-==-==- i ! ! ! ! I ! ! j .i ! ! ! ! ! ! i i ! r=---- ----- ! i i 2020 Thoroughfare Plan City of Farmington ~ 1= --, \ , , , \ " , ..... \ -- -- , I -.... L ..... Legend ~ Existing Minor Arterial ~ Future Minor Arterial ~ Existing Collector Z,,' Future Collector /\/ Existing Minor Collector I \ I Future Minor Collector Ity'Future Roadway /\'/ City Boundary D City Parcel Map . N w.' s Scale o 1000 2000 Feet 1000 NOTE: THIS MAP IS FOR PlANNING PURPOSES ONLY AND SHOULD NOT BE USED FOR EXACT MEASUREMENTS Clly"'F.~"_~o.........MIO a; Q) l.L. r..:.l ~ ~ z.~ Ol '" 0. Ol E! :go. 5~ 0.0 Eo ~ @ !l'~ "'0 .~ .:.L. "", ~O Q) .E"" ctI ~~ 0.. U ~ '" " '" ro 0 en "'-" n;c: 0 C).Q Ol- - E '" '" co c:- c: .!!!- ",,:. :c-c @ >--0 ~ ~ o . ~ {) . ~ Bonestroo _ _ Rosene "" Ander'ik & . \J . Associates Engineers & Architects Bonestroo. Rosene. Anderlik and Associates. Inc. is an Affirmative Action/Equal Opportunity Employer and Employee Owned Principals: Otto G. Bonestroo, PE, . Marvin L. Sorvala. PE. . Glenn R. Cook. PE. . Robert G. Schunicht. PE. . Jerry A. Bourdon. P.E. Senior Consultants: Robert W. Rosene, PE, . Joseph C. Anderlik, PE. . Richard E. Turner, PE. . Susan M. Eberlin. C.P.A, Associate Principals: Howard A. Sanford. PE. . Keith A, Gordon, PE. . Robert R. Pfefferle. PE. . RIChard W. Foster, P.E. . David O. Loskota, P,E, . Robert C. Russek. A.I.A, . Mark A. Hanson, P.E. . Michael T, Rautmann. PE. . Ted K.Field. PE, . Kenneth P Anderson, P.E, . Mark R. Rolfs. PE, . David A, Bonestroo. M.B.A, . Sidney P Williamson, P.E.. L.S. . Agnes M, Ring, M,B.A. . Allan Rick Schmidt, P.E, Offices: St. paul, St, Cloud, Rochester and Willmar. MN . Milwaukee. WI \lIebsite: www.bonestroo.com Memorandum TO: Lee Smick Planning Coordinator FROM: Shelly Johnson DATE: October 13,2000 RE: New Farmington Elementary School- 190th Street Our File No. 141-00-125 The concept layout provided by the architect (see attached) provides two access locations to 190th Street and appears to have an access to the parking lot that is an extension of Everglade . Path. One of the access drives from 190th Street provides access to the bus loading/unloading area on the west side of the building while the other provides access to the parking lot and the passenger pick-up/discharge area located on the east side of the school. This concept does appear to remove the provision of access from 193rd Street. Everl!lade Path Access Allowing an access as an extension of Everglade path has positive and negative connotatiOns. The positive is that it would allow some of the school generated traffic (auto trips only) to use Everglade Path and one block of Everest Trail (191 st Street) to arrive at Everest Path, which is a minor collector. Thus, traffic in that area south of 190th Street would not have to travel on 190th Street. The negative is that those persons living on Everglade Path and Everest Trail (191st) would probably not like the increased traffic coming to/from the school parking lot. Even though Everglade Path has been "stubbed out" to the west to potentially be a local street for more residential development, the fact that it would serve as an access to a school parking lot may cause some residential objections. 190th Street Access . Since 190th is a major collector, we should strive to get a minimum of 1/8 mile between access locations. It appears as though the two school driveways are approximately 450 feet apart. The access to the parking lot needs to be "flipped" to the east side of the lot in order to obtain 600- 660 foot spacing from the bus access. This will still be more than adequate distance from the 2335 West Highway 36 · St. Paul, MN 55113. 651-636-4600 · Fax: 651-636-1311 . . . Lee Smick Page 2 of2 October 13, 2000 Everest Path intersection with 190th Street. Looking to the west, along future 190th Street extension, it would appear as though we would have adequate spacing from the bus access to the future intersection of 190th and the proposed north-south collector. 193rd Street Access It doesn't appear as though it would be economically feasible to construct an 850-foot "roadway" from the south edge of the parking lot to an extended 193rd Street. If the site shifted southerly (topography may prevent that), then 193rd access would be more feasible. Roadwav Improvements Roadway improvements should be discussed, even at this early stage of planning. Requirements would include an extension of 190th Street, at major collector standards, to at least the bus access. Exclusive left and right turn lanes will be required along 190th Street at both school access drives. Access Alone: North Side of 190th Street It should be noted that the location of the school access drives would fix the location of access to future development along the north side of 190th Street. School Generated Traffic We do not know what volumes to expect from the school development as the number of students expected, at capacity, has not been provided. Conclusions The proposed project can function without an Everglade path and 193rd Access. Proper spacing and design of access along 190th can allow for effective access. However, until we know the size of the school and can estimate some volumes, we aren't absolutely certain that Everglade Path wouldn't be a good secondary access. :::: -=: -- -I l.J' I I _Of" . ~~Jl ~--\ c'.i. - -~ 1 '" ,~, I ~ ... "'''' N r""'I{V/ t-::-- f~Fg~:~"7~;;; ~.r - .~ , . , I ~?~ ~~-- 0 .. \ , 3nN3^ '<:I . a I~ ~ I~ l.J "" '" I- '" :J: l- => ~ ~r;t. \1-' ~~{ ~ ~ ~ ~ t\J ... .~ ~" ~ I.... (. ~ ~l'l a : I ~.." '\~ I ~G- !:,~tl :.\~ . ,?i" , .,~ I :.\'\..... ~~:,} ~i I I ~ ~ I- '" "" .> I- ~ I- ot % I- ~ .. .. Ii .. < c '" >- ... ~ 1. Two-family dwellings 2. Agricultural service 3. Commercial recreation uses 4. Water recreation and storage 5. Public buildings 6. Public utility buildings 7. Kennels 8. Solar energy systems 9. Cemeteries 10. Mineral extraction 11. Equipment and mainte- nance storage 12. Feedlot 13. Accessory apartments 14. Public and parochial schools 15. Churches 16. Towers (Ord. 086-177, 3-17-1986; amd. Ord. 088-205. 8-15-1988; Ord. 093-298, 2-16-1993; Ord. 096-383. 11-18-1996) 1 0-3-2 Permitted Uses . 12. Day care center (Ord. 086-177, 3-17-1986; amd. Ord. 2-16-1993; Ord. 096-383. "-18-1996) (8) A-2 Agricultural Preserve District 1. Agriculture 2. Single-family dwellings 3. Public parks and playgrounds 4. Golf courses 5. Stables and riding academies 6. Drainage and irrigation systems 7. Specialized animal raising 8. Greenhouses and nurseries 9. Travel trailer and boat storage 10. Truck gardening 11. Seasonal produce stands 12. Day care center . R-1 Low Density District 1. Agriculture 2. Single-family dwelling 3. Public parks and playgrounds 4. Golf courses 5. Accessory storage buildings 6. Residential care facility serving 6 or fewer persons 597 City of Farmmgtan . 10-3-2 Conditional Uses ......~ '\ 13. Accessory apartments 14. Public and parochial schoOlS 15. Churches 16. Towers 088-205. 8-15-1988; Ord. 093-298, 1. Cemeteries 2. Nursing homes 3. Nonprofit recreational uses 4. Day care facility serving more than 14 persons 5. Hospitals and clinics 6. Public utility buildings 7. Public buildings 10-3-2 .' A~_ ". . (D) . . i 0-3-2 Permitted Uses Conditional Uses 8. Water recreation and water storage 9. Solar energy systems 10. Double and multiple-family dwellings 11. Planned unit devetooments 12. Greennouses and nurseries 13. Townnouses - quad homes 14. Condominiums 15. Accessory apartments ~ 6. Public and parochial schools 17. Churches 18. Congregate care facilities 19. Towers rd. 086-177. 3-17-1986; am r . 8. 2-1-198 ; Ord. 091-246,5-20-1991; Ord. 093-298,2-16-1993: Ord. 094-335, 8-1-1994; Ord. 096-378, 8-19-1996; Ord. 096-383.11-18-1996) 7. Day care facility serving 14 or fewer persons R-2 Medium Density District 1. Agriculture 2. Single-family dwellings 3. Public parks and playgrounds 4. Accessory storage buildings 5. Residential care facility serving 6 or fewer persons 6. Day care facility serving 14 or fewer persons 1. Two-family dwellings 2. Multiple-family dweilings 3. Day care facility serving more than 14 persons 4. Solar energy systems 5. Planned unit deveiopmems 6. 8oaroing house 7. Water recreation and water storage 8. Hospitals and clinics 9. Nursing homes 10. Public utility buildings 11. Public buildings 12. Funeral homes 13. Cemeteries 14. Greenhouses 15. Townhouses - Quad homes 16. Condominiums 17. Accessory aoartments 18. Dental laboratories 19. Public and parochial scnOOlS City of Farmington :97 . . . 1. CITY OF FARMINGTON PLANNING COMMISSION AGENDA Regular Meeting October 10, 2000 at 7:00 P.M. Council Chambers 325 Oak Street CALL TO ORDER 2. APPROVAL OF MINUTES a) August 8, 2000 PUBLIC HEARINGS 3. Conditional Use Permit - Daycare Facility in R-l (Low Density) Zoning District (Continued Public Hearing) DISCUSSIONS 4. Multi-tenant Sign Plan Approval- Barb Ackerman 5. Adjourn Planning Chair: Planning Commissioners: City Staff: Dirk Rotty Todd Larson, Chaz Johnson, Ben Barker, Dan Privette David L. Olson, Community Development Director Lee Smick, Planning Coordinator Michael Schultz, Associate Planner . . . Planning Commission Minutes Regular Meeting August 8, 2000 1. Chair Rotty called the meeting to order at 7:00 P.M. Members Present: Rotty, Larson, Barker, Privette Members Absent: Johnson Also Present: Lee Smick, Planning Coordinator, Michael Schultz, Associate Planner 2. Chair Rotty requested comments for the minutes as submitted for June 27, 2000 meeting. MOTION by Larson, second by Privette to approve minutes. APIF, MOTION CARRIED. 3. Chair Rotty requested comments for the minutes as submitted for July 11, 2000 meeting. Commissioner Larson asked whether discussions concerning the approved 15-foot variance for the length of the cul-de-sacs would need to be revised in the minutes. Planning Coordinator Smick stated that the item on the August 8, 2000 agenda concerning a variance to the maximum cul-de-sac length for Vermillion Grove would override the 15-foot variance and the minutes would not need to be revised. MOTION by Larson, second by Barker to approve minutes. APIF, MOTION CARRIED. Planning Chair Rotty opened all four scheduled public hearings. 4. Planning Chair Rotty introduced the continued public hearing for the Conditional Use Permit application from Colin Garvey to expand the Greenhouse/Landscape business located at 100 5th Street. Schultz updated the Commission indicating that this public hearing is a continuation of the hearing that began on June 27, 2000. Schultz explained that the applicant has not submitted documentation from Canadian Pacific Railroad granting permission for use and crossing of the railroad right-of-way. Additionally, the applicant has not submitted an adequate site plan. Finally, the applicant has not completed the parking lot portion ofthe contingencies stated in an approved Conditional Use Permit granted in May of 1999. Schultz explained that because these items have not been completed, staff recommended that the Planning Commission deny the Conditional Use Permit for the expansion of the Landscape Depot and direct staff to complete a Findings of Fact based on the uncompleted items. MOTION by Larson, second by Barker to close the public hearing. APIF, MOTION CARRIED. MOTION by Larson, second by Privette to deny the Conditional Use Permit and direct staffto complete a Findings of Fact. APIF, MOTION CARRIED. 5. Chair Rotty introduced the continued public hearing for the Middle Creek Estates Preliminary Plat/PUD for DR Horton and Arcon Development. Planning Coordinator Smick stated that at the July 25, 2000 Planning Commission meeting a number of issues was unresolved requiring a continuation of the public hearing. Smick presented the plat and photos from the site to provide the Commission with a view of the site. Smick stated that the Developer submitted a letter to the City on August 3,2000 presenting resolutions to all of the pending issues. Smick stated that the . following revisions were made to the plat. The preliminary plat was renamed to "Middle Creek Estates"; the 128 units outside of the MUSA were removed from the plat and the area is shown as an outlot, the Parks and Recreation Department has approved Outlot D on the plat; Street J was adjusted to a 34-foot back to back roadway; the Developer will be responsible to notify homeowners along the gas line easement that no structures are allowed within the easement; the Developer will follow all requirements from the Engineering Division; and the Developers and Rottlund Homes will coordinate efforts for the installation of the culvert in the D.N.R. wetland 353W. Smick also presented a letter from Dakota County stating that the plat "does not provide for local street integration with County highways as called for in the Contiguous Plat Ordinance". Smick stated that the County was concerned the plat does not contain a north/south collector street. Smick presented the plat for Vermillion Grove to the north of Middle Creek Estates showing the north/south collector street has met the requirements ofthe City's 2020 Thoroughfare Plan. Chair Rotty asked for comments from the applicant. Larry Frank, Arcon Development, stated the Park Dedication Fee would be both a combination of land and cash donations for the park. Frank stated that they would save trees along Pilot Knob Road and the northwest area of the plat. Frank proposed to remove the existing cul-de-sac in this location to save the trees. Frank explained that the houses along the gasline easement would be set off the easement by at least 15 feet. . Chair Rotty asked the Developer's engineer what was the time frame used in his calculations for 15 inches of rain. The engineer responded that it was a 24-hour time frame. Chair Rotty commended the Developers for their efforts in saving trees on the property. Chair Rotty asked how the Developer would notify potential homebuyers of the gasline easement. Don Patton, DR Horton, explained that all homebuyers in the development would be given a packet of information disclosing the gas line easement and informing the homebuyer that no structures are allowed within the easement. Chair Rotty expressed to the Developer that they provide the plat in models showing the gas line easement and making it clear to potential homebuyers of the easement situation. Chair Rotty asked for comments from the Commission. Commissioner Larson asked whether the Wilson property would be permanent and the Developer would grade around the property. Larry Frank explained that they would grade around the property and provide a road to the Wilson property and build a driveway for property. Chair Rotty and Commissioner Larson were concerned about the plat and would have preferred a cleaner plat be sent to the City Council. . Commissioner Barker asked when the next Dakota County Plat Commission would meet. Planning Coordinator Smick stated that they would meet on the following Monday. Smick stated that staff would attend the meeting showing the north/south collector between Middle Creek Estates and Vermillion Grove. Commissioner Barker asked if the Dakota County Plat Commission could deny the plat for unforeseen circumstances and thereby effecting the Planning Commission's approval of the plat. Smick stated that the letter from the Dakota County Plat Commission was a recommendation to reduce traffic on their system and because they do not have jurisdiction of local streets, the decision of the Planning Commission would not be affected. Smick also stated that staff has had a number of coordination meetings concerning access to CSAH 31 and from these meetings, the accesses have been approved. . . . MOTION by Larson, second by Privette to close the public hearing. APIF, MOTION CARRIED. MOTION by Larson, second by Barker to approve the Middle Creek Estates Preliminary Plat. APIF, MOTION CARRIED. 6. Planning Commission Chair Rotty introduced the Conditional Use Permit for a continuation of a non-conforming use at 301 Pine Street. Associate Planner Schultz presented the staff memo to the Commission. Schultz stated that the property is zoned I-I and the Comprehensive Plan shows the lot as commercial. The applicant proposes to sell 10 to 15 cars on lot and possibly 30 if there is adequate room for the cars. Schultz stated that the applicant would clean up the property by painting the interior and exterior of the building. The applicant, David Thurston, acknowledged that he was excited about opening a business in the City. Chair Rotty asked about signage. Schultz stated that the applicant would have to apply for a sign permit. Mr. Thurston stated that he is aware of the sign permit requirements. Chair Rotty asked Mr. Thurston if he understands that the he is not allowed to repair automobiles on the site. Mr. Thurston agreed to that requirement. Commissioner Larson questioned if Mr. Thurston would buy the property. Mr. Thurston answered that it is a 3-year lease with an option to purchase the property. Commissioner Larson requested that the applicant and staff work with Dakota County and the Minnesota Pollution Control Agency because a portion of the property was utilized as the Elm Park dumpsite as well as potential oil spills on the property. Chair Rotty asked if Mr. Thurston would carry flood insurance. Mr. Thruston agreed to that request. MOTION by Larson, second by Privette to close the public hearing. APIF, MOTION CARRIED. MOTION by Larson, second by Barker to approve the Conditional Use Permit for the continuation of a non-conforming use within an I-I zone contingent on the following: 1) The applicant completes the exterior improvements to the building within 60 days of operation of the proposed use. 2) The applicant submits a landscape plan to the City for any landscape improvements 3) No automobile or motor repair takes place on the site. 4) All existing exterior lighting is in working condition within 30 days of operation of the proposed use. 5) Staff and the applicant work with Dakota County and the Minnesota Pollution Control Agency. 6) The applicant carries flood Insurance. APIF, MOTION CARRIED. 7. Planning Commission Chair Rotty introduced the public hearing to consider a variance to the maximum cul-de-sac length for the Vermillion Grove Preliminary Plat. Planning Coordinator Smick presented the staff memo stating that a separate public hearing was required for this variance which was approved by the Planning Commission at the July 11, 2000 meeting. Smick stated the City Attorney's office required that a public hearing for the variance be held separate from the approved Vermillion Grove . . . Preliminary Plat that was approved by the Planning Commission on July 11, 2000 and by the City Council on July 17, 2000. At the City Council meeting, the approval was contingent upon approval by the Planning Commission of the variance to the maximum cul-de-sac length of 500 feet. Smick stated that the applicant, Rottlund Homes seeks a variance to the maximum cul-de- sac length of 500 feet by 115 feet. Michael Noonan, Rottlund Homes stated that he supported the recommendation by staff. Chair Rotty stated that he would support the variance, however the issue of cul-de-sac lengths should be a part of the Zoning Code Update discussions. MOTION by Barker, second by Privette to close the public hearing. APIF, MOTION CARRIED. MOTION by Privette, second by Barker to approve the variance to the maximum cul-de-sac length of 500 feet by 115 feet. APIF, MOTION CARRIED. 8. Chair Rotty opened the discussion item concerning the consideration of single-family models to be constructed prior to the installation of streets and utilities. Planning Coordinator Smick explained that the City has received a number of requests from developers to receive approval for constructing single-family models prior to street and utility installation in order to show models. Smick explained that City concerns include emergency vehicle access and water access to the site. Smick further stated that the City is reviewing whether paved roadways would be required or Class 5 would be efficient. Commissioner Larson stated that he would not be in support of allowing the models to be constructed before streets and utilities are installed. Commissioner Privette was concerned about the safety issues concerning the lack of utilities and potential muddy roads. Commissioner Barker also agreed with Commissioner Larson and Privette. Chair Rotty asked if this would be a City policy or written into the development contract. Smick stated that staff has not determined where the issue would be located because further discussions with the Planning Commission and City Council are required. Smick also stated that the Fire Department would approve Class 5. Michael Noonan, Rottlund Homes explained that they have made a request to the City to build models before streets and utilities are installed. He further stated that the reason for this request is to get ahead on the construction in the spring. Mr. Noonan understands that no temporary certificate of occupancy would be allowed for a sales office or model until they would meet the requirements of the City such as access and safety if they would change the policy. He proposed that staff review other jurisdictions in the metro area to discover that they allow models before streets and utilities. Commissioner Larson would like to determine the phasing of streets, utilities and other issues for subdivisions. Chair Rotty requested that staff research other jurisdictions. He also acknowledged the Commission's reservations at approving models before streets and utilities and stated that the Commission would not support the proposal at this time. 9. There being no further business the Commission agreed to adjourn. . . . City of Farmington 325 Oak Street, Farmington, MN 55024 (651) 463-7111 Fax (651) 463-2591 www.ci.farmineton.mn.us TO: . City Planning Commission Michael Schultz ,f\,.1iJ Associate Planner Y FROM: SUBJECT: Conditional Use Permit - Construct Day Care Facility within R-l (Low Density) Zoning District (Continued Public Hearing) Applicant: Karol & Mike Bednar DATE: October 10,2000 INTRODUCTION This is a continued public hearing from the September 12, 2000 Planning Commission meeting. Karol and Mike Bednar have submitted for a Conditional Use Permit to construct a Day Care Facility serving 14 or more persons within an R-l (Low Density) Zoning District proposed at the northeast comer of Pilot Knob Rd and 190th Street. DISCUSSION The Planning Commission agreed to continue the public hearing after questions arose from neighborhood residents concerning the amount of traffic generated from the proposed land use and to allow the Commissioners to review the previous traffic count and analysis that occurred in April and May 2000. Attached are copies of the traffic count and analysis that took place from Friday April 28, 2000 to Tuesday May 2, 2000, the resulting memos from staff to the City Council. Also attached is a recent analysis conducted by Shelly Johnson, Bonestross Engineering, dated October 2, 2000. In Mr. Johnson's memo he assumes that the anticipated number of vehicles traveling in and out of the daycare/preschool facility will be 500 trips per day (250 trips in/250 trips out). Mr. Johnson also assumes that half of the vehicles will travel north on English Ave and the other half will travel south to 19Sth Street. Based upon these assumptions Mr. Johnson recommends that no additional traffic controls be added along English Ave; specifically a three-way intersection at 189th Street. Mr. Johnson also recommends against closing off the northbound travel of English Ave at 189th Street in order to allow the street to function as "a facility that handles "short" trips along the east side of CSAH 31". . . . RECOMMENDATION Based on the criteria for approval of Conditional Uses as found in Section 10-8-5 (c) of the Zoning Code and also the findings of Mr. Johnson involving the traffic study along English Ave; Planning Staff recommends approval of the Conditional Use Permit to construct a daycare facility serving 14 or more persons within the R-l (Low Density) Zoning District contingent upon the following: 1) The property be platted prior to a building permit being issued for the construction of the building; 2) The proposed trees along English Ave are planted within the boulevard and to the City standards outlined according to Section 10-6-14 of the City Code; 3) An additional luminaire be added near the entrance of the property to provide driveway lighting; 4) The applicant submit for staff approval the addition of brick veneer as detailing on the building; 5) The applicant indicate the placement of a six (6) foot high dumpster enclosure, contingent on staff approval, along the perimeter of the proposed parking lot; 6) The applicant submit for staff approval the placement and variety of plantings around the perimeter of the parking lot; 7) The applicant submit a plan that complies with the City's standards and requirements for the construction of parking lots; 8 ) The applicant submits landscaping and parking lot sureties in an amount acceptable to the Planning Coordinator and City Engineer. Respectfully Submi ~- Michael Schultz Associate Planner cc: Mike & Karol Bednar . . . Memorandum TO: Mike Schultz Associate Planner FROM: Shelly Johnson Director, Traffic Engineering and Transportation Planning DATE: October 2, 2000 RE: Traffic Analysis - Proposed Day Care/Pre-School Facility at Pilot Knob Road and 190th Street Our File No. 49-Gen A proposal to construct a day care facility at the northeast corner of Pilot Knob Road and 190th Street has been presented to the City of Farmington. The proposed 7,625 square foot building would house a day care facility and a pre-school facility. This traffic analysis will address the following issues: . Traffic impact of the proposed facility on the area roadway system . Effect of the development on English Avenue as it relates to traffic control on English Avenue at 190th and 189th Streets . Citizen concerns/ideas for English Avenue at 189th Street Development Traffic Impact The development proposal consists of building a day care facility with anticipated use of day care and pre-school activities. The projected student count is 110. The projected vehicular trips generated on a daily basis is 500 (250 in; 250 out). This is based on average trip rate data presented in the Institute of Transportation Engineers (ITE) report titled "Trip Generation", 6th Edition, 1997. Given the site access is proposed to occur along English Avenue, it can be estimated that the directional distribution of traffic on English A venue would be 50 percent to the north and 50 percent to the south. This would add approximately 250 vehicles per day to English Avenue traffic on either side of the English Avenue access. Traffic count data collected by the Farmington Police Department in April and May of 2000 indicated a 24-hour volume of 860 vehicles for a weekday along English Avenue. Peak hour volumes totaled approximately 100 vehicles. The counts were conducted in the 18800 block of English Avenue. The proposed development will increase the volumes on English Avenue to approximately 1,000 vehicles per day. Note that not all of these volumes will be "new trips" as the day care/pre-school trips are being made today, but to different facilities. . The volumes generated by the proposed development will not create any land use traffic congestion on the area roadway system. Traffic Control -:" .".. '-'~' The volumes generated by the development will not create the need to change the existing traffic control at the intersections of English Avenue at 190th Street or 189th Street. Presently, English Avenue is controlled by stop signs at 190th Street and 187th Street. At the English A venue/189th Street intersection, 189th Street is controlled by a stop sign. The projected volumes at those locations would not warrant all-way stop control and sight distance is sufficient so as not to warrant any change in the existing traffic control. It should be noted that placement of all-way stop control at the English A venue/189th Street intersection, would, if installed, cause needless delay for English Avenue traffic that is not necessary or warranted. That traffic is already required to stop at 190th and at 187th. The introduction of stop signs on English Avenue at 189th Street would, over time, tend to be ignored by traffic and drivers would tend to "roll" through the stop signs. Drivers would wonder why this stop sign was there since traffic on 189th is very minimal. The more stop sign controls installed, those not evident to serve a purpose, the more drivers tend to ignore them and "roll" through the locations. This is a potentially hazardous situation that needs to be avoided citywide. . Northbound Ene:lish Avenue Closure A citizen suggestion has been to close English Avenue-to northbound traffic just south of the intersection of 189th Street. This is not recommended for the following reasons: . English functions as a facility that handles "short" trips along the east side of CSAH 31. It provides access to development that has occurred along the east side of CSAH 31. Prohibiting northbound traffic at 189th Street would force "short" trips to use CSAH 31 which is not desirable along that road which functions as an arterial. . The volumes on English, projected at approximately 1,000 vehicles per day, do not cause any traffic congestion - closure is not necessary and would cause more problems than it would solve. . . . . the 18800 block of English A venue. The proposed development will increase the volumes on English Avenue to approximately 1,000 vehicles per day. Note that not all of these volumes will be "new trips" as the day care/pre-school trips are being made today, but to different facilities. The volumes generated by the proposed development will not create any land use traffic congestion on the area roadway system. Traffic Control -.~ ..... ..~. The volumes generated by the development will not create the need to change the existing traffic control at the intersections of English Avenue at 190th Street or 189th Street. Presently, English Avenue is controlled by stop signs at 190th Street and 187th Street. At the English A venue/ 189th Street intersection, 189th Street is controlled by a stop sign. The projected volumes at those locations would not warrant all-way stop control and sight distance is sufficient so as not to warrant any change in the existing traffic control. It should be noted that placement of all-way stop control at the English A venue/189th Street intersection, would, if installed, cause needless delay for English Avenue traffic that is not necessary or warranted. That traffic is already required to stop at 190th and at 187th. The introduction of stop signs on English Avenue at 189th Street would, over time, tend to be ignored by traffic and drivers would tend to "roll" through the stop signs. Drivers would wonder why this stop sign was there since- traffic on 189th is very minimal. The more stop sign controls installed, those not evident to serve a purpose, the more drivers tend to ignore them and "roll" through the locations. This is a potentially hazardous situation that needs to be avoided citywide. Northbound Emdish Avenue Closure A citizen suggestion has been to close English Avenue-to northbound traffic just south of the intersection of 189th Street. This is not recommended for the following reasons: . English functions as a facility that handles "short" trips along the east side of CSAH 31. It provides access to development that has occurred along the east side of CSAH 31. Prohibiting northbound traffic at 189th Street would force "short" trips to use CSAH 31 which is not desirable along that road which functions as an arterial. . The volumes on English, projected at approximately 1,000 vehicles per day, do not cause any traffic congestion - closure is not necessary and would cause more problems than it would solve. 1 0-8-5 , 0-8-5 . 2. The approved site plan and all attached conditions shall be filed by the petitioner with the Zoning Officer within thirty (30) days of final approval. Any development contrary to the approved plan shall constitute a violation of this Title. (C) A conditional use shall be approved if it is found to meet the following criteria: 1. The proposed use conforms to the district permitted and conditional use provisions and all general regulations of this Title. 2. The proposed use shall not involve any element or cause any conditions that may be dangerous. injurious or noxious to any other property or persons and shall comply with the performance standards listed below. 3. The proposed use shall be sited, oriented and landscaped to produce harmonious relationship of buildings and grounds to adjacent buildings and properties. 4. The proposed use shall produce a total visual impression and environment which is consistent with the environment of the neighborhood. . 5. The proposed use shall organize vehicular access and parking to minimize traffic congestion in the neighborhood. 6. The proposed use shall preserve the objectives of this Title and shall be consistent with the Comprehensive Plan. 7. Additional requirements with respect to conditional uses in the Conservation District include the following: (a) Filling a wetland shall not exceed the flood storage capacity requirements for the wetland. (b) The proposed development shall not result in unusual maintenance cost for road and parking areas or the breaking and leaking of utility lines. (c) Development shall be permitted in such a manner that the maximum number of trees shall be preserved. The remaining trees shall contain at least fifty percent (50%) of the canopy coverage. . 294 City of Farmin.gtan 1 0-8-5 . . . 294 , 0-8-5 (d) Development shall be accomplished only in such a manner that on-site soil erosion shall be minimized both during construction and when construction activity is completed. (e) Wetlands and other water bodies shall not be used as primary sediment traps during development. (f) The quality of water runoff and water infiltration to the water table or aquifer shall remain undisturbed by the development of the site. (g) The type and density of land use proposed tor the site shall be suited to the site. Bedrock conditions shall not present a threat to the maintenance of ground water quality and shall not fail to adequately correct problems due to soil limitations including bearing strengths, shrinkwell potential and slope stability. (Ord. 086-177, 3-17-86) 8. Additional requirements for conditional uses in flood plain districts are listed in Chapter 10 - Flood Plain Management, of this Title. (Ord. 093-323, 12-6-93) 9. Conditional uses in the flood plain districts shall also be subject to the following considerations: (a) The danger to life and property due to increased flood heights or velocities caused by encroachments. (b) The danger that materials may be swept onto other land or downstream to the injury of others. (c) The ability of proposed water supply and sanitary systems to prevent disease, contamination and unsanitary conditions. (d) The susceptibility of the proposed facility and its contents to flood damage and the effect of such damage on the individual owner. (e) The availability of alternative locations not subject to flooding for the proposed use. (f) The compatibility of the proposed use with existing and anticipated development. City of Farmington. English Ave - Land Uses and Traffic Control Device Locations .\V~f~"inte~se~~ ~~~ ~rD D~'I III ~ ~~ p~K -11 r B.udgetMart ~ "N / If I I ~I~~~r Store ~I I I ~ ~ ~ 16 Townhome Units ILl II Dominoe's Pizza ~ ,~I I ~ II )f- ;::: -I' 1~ 83RD 5IT-\A - n ~ I ~...... I:I=D 16 Townhome Units - \ - -' ' II)H H)yt - \..- JP-1R3R[~~ ~ ""- ~ \" IT T--,~ I · D Multi-family Townhomes -'r- I! right turn only' 1/ / ?~ 32 units (mostly 2-3 bedrooms) --'-~ '" / ~ II 0& Future Commercial 12<~ ~ ~ "-<LJ ~ I ,---- (Zoning B-1) ~___ ~ - --/ "~7!JiiiiiJ =g ( I I I W " ClIIlao~6Townh:eU~itsll I Super Americad.. ffl~ I I I I I I L-J Sf~> ~I ~J ><ITlJJ I I I I (8 -I~ LIJIO ~ l / ~ ~ ~~ =~~~ \lIliEF{f\ HighWaYDiVide~- =Z;=. ~~ ~~ ~ =~- _ [ C---" ~. I - [ c-- ~186Tc_sTLWI EEE& full intersecti'!!!!::;:: = . I I j i I ~=- ~-~~ ~ -, ~ t--, ~ 11' ITytSIW~ ~ \ : ~ ~ 188f1Yi ~ -f-- =u f-- ~yy o \ ~ '1.[ T I ( t----l I \i\N 18ihrl1 ~ ;;o~ o ~ ' .~ - ........ ~9_01trsr" ~ \ ~ '\ T I / / ~ '[U G Location of Stop Signs N _':t"~cl;(o,,~~ D't<G":Scale . I Pi ~,~^ ;~"~'fr'''') -\-t<,';:\;-c. . W E 500 0 500 Feet ~' ,s \~ \ .~ ) ~ ~- \- r- t- )t- I-- '-- ~ ~ <- <- j . J V~\ J:' ~d \3r\S:==\ ~ = < I full intersection.;;;: