HomeMy WebLinkAbout03.12.96 Planning Packet
.
4.
. a.
b.
c.
d.
5.
.
AGENDA
PLANNING COMMISSION
REGULAR
MARCH 12, 1996
7:00 P.M.
1.
CALL TO ORDER
2.
APPROVE MINUTES
February 13, 1996
a.
3.
PUBLIC HEARINGS
7:00 P.M. - Request for Rezone - Lots 5 & 6, Block 21, Original
Town. of Farmington from B-2 to R-2
7:15 P.M. - Discuss Preliminary Plat of TroyHil1 2nd Addition
7:30 P.M. - Discuss Preliminary Plat of the Townhouses of
Nelsen Hills Farm
7:45 P.M. - Discuss Request to Move House onto West Half of
Lot 7, Block 2, pine Knoll Addition
a.
b.
c.
d.
DISCUSSION
Request for Final Approval of TroyHil1 PUD
Regulation of Outdoor Sales in B-1 and B-2 Districts
Priority for MUSA Expansion
Special Meeting - March 26, 1996
ADJOURN
.
AGENDA REPORT
PLANNING COMMISSION
REGULAR
MARCH 12. 1996
1. CALL TO ORDER
2. APPROVE MINUTES
3 . PUBLIC HEARINGS
a. Request to Rezone Lots 5 & 6. Block 21 from B-2 General Business to R-2 Medium Density
Residential
James and Betty Klose have an offer on their house at 404 Oak Street, but the buyer
appears to be unable to get a mortgage because of the business zoning on this property.
When the original Comprehensive Plan was drafted in 1971, the business district had
already jumped over 4th Street with the construction of Tom Thumb at 5th and Elm Streets.
This was followed by the construction of the Motor Parts building at 4th and Oak. The
popular belief at the time was that the business district would keep expanding from the
historic center at 3rd and Oak and that both Lots 5 and 6 would soon be required for
business uses. While nothing happened to reaffirm this belief in 1982 when the plan was
updated, the property continued to be designated as B-2 General Business.
In 1983, the Deegan house was remodeled, following Planning Commission approval, into a
home occupation and residence on the first floor and an accessory apartment on the second.
.AS indicated during the February meeting, the lack of interest in this property for
business use during the past 25 years suggests that the zoning classification should be
changed to residential. Another factor that suggests rezoning is the current demand for
large old houses in the neighborhood adjoining downtown. In the recent past, there have
been many houses that have been upgraded from multiples to single family dwellings. The
Design Study that was done prior to the development of the East Farmington POD and the
Prairie Wqterway pointed out the value of these neighboring housing units to the Downtown.
Recommendation
Forward a recommendation to the City Council endorsing the request to rezone Lots 5 and 6,
Block 21 from B-2 General Business to R-2 Medium Density Residential.
b. Request to Approve the preliminary Plat of TroyHill 2nd Addition
Builders Development, Inc., has proposed a 61 lot single family subdivision as its first
phase of TroyHill POD. It will be known as TroyHill 2nd Addition and is situated between
Everest Path and Fair Hills plat, south of 190th Street and north of TroyHill 1st
Addition. The plat conforms with the preliminary PUD approved in February by both the
Commission and City Council.
The Developer has indicated that the entire POD site will be graded during the development
of the 2nd Addition. The City Engineer has several recommendations regarding grading as
follows:
.
a) The concentrated runoff along the west property line in the area of Lots 81 to 84 of
the PUD shall be converted to sheet runoff when the lots are regraded.
b) The Developer shall be responsible for rough grading of 190th Street in preparation for
paving during construction of the 3rd Addition. A formula will need to be developed by
Planning Agenda - 3/12/96
Page 2
the City Engineer for allocation of costs to benefited property so that the lots in
TroyHil1 and Nelsen Hills Farm will share equally in 190th Street development costs.
.
c) The
for
Developer's engineer will need to verify that site grading will eliminate the need
3 foot subcuts under both streets in the plat. The City currently requires 2 feet.
d) The profile of Everest Path needs to be revised to eliminate the "roller coaster"
effect of the proposed grade changes between 193rd Street and Evenston Drive.
In addition, the City Engineer recommends the dedication of Outlots A and B and a crushed
rock access to Outlot A between Lot 7, Block 2 and Lot 1, Block 3 to discourage lot owner
appropriation of the access, plus a notation on the plat that temporary 10 foot utility
easements are required along street frontages lof lots adjoining the plat. They are
requested for Lots 62, 75 and 75 of the PUD plan.
Another plat requirement will be oversized easements to accommodate future access to deep
sanitary and storm sewer lines; a total of 30 feet or 15 feet on each side of the property
line separating Lots 17 and 18, Block 1, and 20 feet or 10 feet on each side of the
property line separating Lots 2 and 3, Block 3; and Lots 8 and 9, Block 1.
The Parks and Recreation Director has recommended that the Developer install the bikepath
during construction of other plat improvements so that lot owners are aware of the
bikepath when they purchase adjoining lots. The path will need'to be regraded both at the
south and north end to a maximum grade of eight percent to assure that it will be
accessible for use by the handicapped. In addition, the Parks and Recreation Director
requests that the Developer install an eight by twelve box culvert under 190th Street to
tlteliminate an at grade bicycle crossing. The extra costs associated with the trail will be
credited against the park dedication fees for the entire PUD.
Both Outlots A and B will be dedicated to the City. The Staff would request the planting
of wetland root stock in the stormwater treatment pond to speed the healing of this
permanent waterbody.
The tree planting on the berm separating lots on the north edge of the site from 190th
Street are a welcome addition to the plat. The plan indicates that there will be 12 Black
Hills Spruce trees.
The Water Board expects the dedication of Lot 16, Block 4 for a future well site, the cost
of which would be credited against the water area charge for the plat.
The final plat must include a right of access dedication to the City of Farmington for
lots adjoining 190th Street. This will prevent any future direct access to this collector
street by adjoining property owners.
Recommendation
Approve the preliminary plat of TroyHil1 2nd Addition subject to comments from City Staff
and recommend that it shall also be approved by the City Council.
.
,Planning Agenda - 3/12/96 - Page 3
..
Request to Approve the Townhouses of Nelsen Hills Farm Preliminary Plat
The preliminary plat is approximately the same layout as submitted in the revised site
plan for the PUD amendment. The Dakota County Plat Commission has indicated that this
subdivision meets its general requirements but requires that noise mitigation elements
shall be incorporated into the development. This would appear to be an issue to be
discussed between the Developer and the County Engineer's office, since the Developer has
both natural cover and buffer plantings in place that will be removed when Pilot Knob Road
is upgraded from two to four lanes. This should happen soon since the City Engineer has
requested that the site should be graded now to accommodate the pilot Knob Road
improvements.
Some revisions will need to be made to the plat as submitted, since the building on Lot 4
is considerably closer to Pilot Knob Road than proposed on the revised site plan submitted
earlier. The structure is within 25 feet and should be 40 feet as discussed. This
difference can be made up by moving the houses on Lots 1 and 2 ~ive feet closer to Euclid
Path, where the closest unit will be 20 feet from the street right of way and moving Lots
3 and 4 ten feet closer to Lots 1 and 2. The separation between these units will then be
40 feet rather than 50 feet.
The Developer will need to initiate a request to the City Council to vacate the utility
and drainage easements on the lot lines separating Lot 1 and 2, Block 1 of the Third
Addition, as well as the utility easement along the original right of way dedication for
Pilot Knob Road. A new utility and drainage easement of 10 feet must be created along
Pilot Knob Road. A relatively wide (25 feet) utility easement is necessary along the east
4Itside of Lots 5 through 8 to accommodate sewer and water service to six of the units.
Recommendation
Approve the preliminary plat of the Townhouses of Nelsen Hills Farm and recommend that the
City Council also approve the preliminary plat.
d. Request to Move House onto the West Half of Lot 7, Block 2, Pine Knoll.
John H. Schmidt has an opportunity to purchase the vacant half of this lot and move in a
house that is located in an area that will become a freeway access ramp. The City
Building Official has said that the building is sound and the applicant has located the
structure on the property as per the attached site plan. One problem that comes to
surface is that the building setback on the moved in structure is 12 feet closer to the
street than the existing house on the corner. The Zoning Ordinance specifies that, while
20 foot setbacks are acceptable, older neighborhoods were likely to have had deeper
setbacks which then establish the minimum requirements for that block. The ordinance also
says that the Board of Adjustment (Planning Commission) may allow front yard setback
variances of up to five feet. In this particular instance, the moved in structure would
be required to be at least 27 feet from the street right of way line. The lot appears to
be deep enough to accommodate the extra setback. The enclosed photographs indicate the
housing style, which appears to fit within the neighborhood.
.
A neighborhood concern brought to the attention of City Staff is the potential for on site
wetlands. Information in the hands of Staff indicates that the wetlands are off the site.
If the question persists, the applicant may need to hire expert help to establish the
wetland boundary. This delineation can be completed for less than $200.00.
Planning Agenda - March 12, 1996 - Page 4
411iecommendation
Approve the move as requested subject to:
a) the submission of a certificate of insurance from the house mover and a surety from the
applicant to satisfy the City Finance Director that improvements will be made to the
house as specified by the Commission;
b) a clarification as to the limits of wetlands on site; and
c) a deadline as to when required improvements must be completed.
4. DISCUSSION
a. TroyHill PUD Plan Report
The plan report on TroyHill PUD has been revised and resubmitted. The information meets
the requirements of the City Code. The Developer has indicated that he may wish to
accelerate platting of the PUD and, possibly, will split the proposed second phase and
submit a smaller portion earlier than is indicated in the tentative schedule in the PUD
plan report.
Recommendation
Approve the Final PUD Plan as submitted and recommend that the City Council also approve
.he PUD.
b. Regulation of Outdoor Sales
The question of regulating outdoor sales was brought to the attention of the City Council
when the staff received an unsigned complaint about the new equipment rental business on
Spruce Street. The Police Department discussed the complaint with the proprietor of the
rental business and all equipment was removed from the street right of way.
The Planning Staff, after consulting with the City Attorney, notified this business owner
that a conditional use hearing would be necessary, to which he responded that he was
looking for a business location that he could purchase. One that interested him very much
is situated outside of the City boundary. He was told then that the conditional use
hearing could be delayed until Spring.
Staff is still unclear about how to regulate this type of business since screening of the
tools that may be rented will put the business at a disadvantage. The visible equipment
in this yard clearly helps to generate business. Staff has contacted both Lakeville and
Rosemount for some background on similar regulations in these cities. In Lakeville,
outdoor storage is regulated in several ways: it is always considered a conditional use;
it must be fenced from neighboring residential uses; it must be placed on grass or other
dust free surface; the lighting must be directed toward the material displayed; and the
material must not displace required parking. Lakeville does require screening but
interprets it as landscaping in the form of low hedges and/or trees that shade the site.
.It would appear that the Farmington Ordinance is currently okay and that each conditional
use request for outdoor sales can be discussed using similar guidelines.
, . . . ' Planning Agenda - 3/12/96
Page 5
Recommendation
.uggest no change in
this site until late
the current ordinance and delay requesting.a specific application at
Spring when the future location of the business is more certain.
c. Priority for MUSA Expansion
In responding to the City request to expand MUSA by 17 acres for the completion of
platting within prairie Creek PUD, the Metropolitan Council staff offered the following:
The 17 acre parcel is an orderly addi tion to the MUSA and placing the ponding
area in to the rural area conforms wi th adj acen t rural use of the land. The
Council should inform Farmington that acceptance of this proposed unique minor
amendment should not be viewed as a change in Council policy for evaluating the
need for future additions to the City's MUSA.
In essence, this says that there is no justification for MUSA expansion based upon current
growth forecasts, but there is some logic in completing this PUD. To provide some
background for this attitude, the City just received Preliminary Housing Forecasts for all
communities in the Metropolitan Area for the years 2000, 2010, and 2020. They were
calculated for the three growth options that are now being discussed by the Metropolitan
Council, which are described as Current Trend, Concentrated Development, and Growth
Centers. The followings uses only Current Trend through the ye~r 2000 with actual records
from two additional years of development history.
.
Far.mington Household Forecast
Contrasting Actual 1990-1993 with 1990-1996
~ per.mits
1990 67
1991 68
1992 88
1993 119
1994 359
1995 345
1996 300 *
1997 300 *
1998 300 *
1999 300 *
2000
* - Estimated
~
Metropolitan Council
2064
2064
2406
2390
3110
4310
3200
Based upon the permits that have been issued through 1995, there are fewer than 100
.ermits which will be available through the year ~999. As ~f March 7, 1996, f~ft~ of
hese have already been issued. In essence, Farm1ngton aga1n must prove that 1t 18 a
"Metropolitan Area Hot Spot" before moving on to discuss MUSA needs. The Metropolitan
Council does not appear to be ready to discuss MUSA expansion beyond the year 2000 at the
. '
.Planning Agenda
3/12/96
Page 6
moment because Farmington's share of the Metropolitan Area development pie is
significantly reduced when the other two development options (Concentrated Development and
.rowth Centers) are forecast. Assuming that some corrections can be made in the current
rend option, the Planning Staff will attempt, during the meeting, to identify priorities
for MUSA expansion that were discussed generally during the City Council/Planning
Commission workshop on February 21, 1996.
d. Special Meeting
Chair Craig Schlawin has called a special meeting of the Planning Commission in response
to a request from Progress Land Company to review the preliminary plat of prairie Creek
Fourth Addition. The meeting will be held on March 26, 1996 at 7:00 P.M..
~.~
~
...
Charlie Tooker
City Planner
.
.