Loading...
HomeMy WebLinkAbout03.14.23 Planning Packet Meeng Locaon: Farmington C ity H all 430 T hird Street Farmington, M N 55024 P L A NN I N G C O M M I S S I O N R E G U L A R M E E T I N G A G E N DA M arch 14, 2023 7:00 PM 1.C A L L TO O R D E R 2.A P P R OVA L O F M I N U T E S (a)A pprove P lanning C ommis s ion Minutes 3.P U B L I C H E A R I N G S (a)A mendment to C ondi!onal Use Permit to allow for the Expansion of a Charter S chool within the B-2 Zoning D is trict - G reat O aks A cademy - 115 Elm S treet (b)Request for a C ondi!onal Use Permit to A llow the Construc!on of a U!lity H ut w ithin the I -I ndus trial Zoning D istrict (c)Variance Reques ts to Minimum L ot S iz e within the A -1 Zone - Patrick & D aw n D evney 4.A D J O U R N TO :P lanning C ommis s ion F R O M :Tony W ippler, P lanning M anager S U B J EC T:A pprove P lanning Commission M inutes DATE:March 14, 2023 I N T R O D U C TI O N Aached, are the minutes from the February 14, 2023 regular mee$ng. D I S C U S S I O N N A A C T I O N R EQ U E S T E D A pprove the minutes from the February 14, 2023 regular mee$ng. AT TA C H M E N TS : Type D es crip$on Backup M aterial February 14, 2023 Regular P lanning Commission Minutes TO :P lanning Commission F R O M :Tony W ippler, P lanning Manager S U B J EC T:A mendment to C ondional Use Permit to allow for the Expansion of a Charter S chool within the B-2 Zoning D is trict - G reat O aks A cademy - 115 Elm S treet DATE:M arch 14, 2023 I N T R O D U C TI O N G reat O aks A cademy is s eeking an amendment to a condional use permit to allow further expansion of their Charter S chool located at 115 Elm S treet. G reat O aks A cademy was granted a condional use permit by the city's P lanning C ommis s ion on January 11, 2022 to establis h the C harter S chool w ithin the former grocery store building located at 115 Elm S treet. The propos ed expansion includes renovang and occupying the exisng strip center on the eas t s ide of the property for addional classrooms, adding a gymnasium expans ion onto the northw est side of the exis ng s trip center, and renovang the interior of the northern most poron of the grocery store building currently hous ing @ Bat into classrooms. G reat Oaks A cademy Review G reat O aks A cademy is a tuion-free, classical charter s chool built on the pillars of Rigor, L iterature, Wonder, and V irtue. The school is deeply commi7ed to building a school with rigorous academics , high expectaons , and a strong emphas is on developing character while encouraging each student's natural s ense of w onder at the w orld. The mis s ion of G reat O aks A cademy is to provide students w ith a clas s ical, liberal arts educaon that is rigorous, literature-rich, wonderous, and virtuous. The vis ion is to graduate young adults w ho: A re fully prepared for the rigors of college and career Value truth, beauty, and goodness Pos s ess a lifelong passion for learning A re acve parcipants in their communies Recogniz e the value of their contribuons A ccording to the school's 2021-2022 A nnual Report, the enrollment of the school for the 2021-2022 s chool year w as 188 students in kindergarten through 5th grade. The report indicates up to 316 s tudents enrolled in 2022-2023 in kindergarten through 6th grade. Enrollment projecons for the s chool s how s an increas e in enrollment to 365 students (k-7th) in 2023-2024, 463 students (k-8th) in 2024-2025, and 515 s tudents (k-9th) in 2025-2026. The 2021-2022 A nnual Report also indicates that the school had a s taff of 29 people. D I S C U S S I O N G reat O aks A cademy is requesng approval to amend a previous ly approved condional use permit to allow the expans ion of a C harter S chool at the property located at 115 Elm S treet. The P roperty is currently ow ned by Farmington 115, L L C (Wellington Management C ompany). The property is within the B-2 (D ow ntow n Busines s ) Zoning D istrict and schools are lis ted as condional us es. A s s how n on the a7ached s ite plan and floor plans the proposed expans ion cons is ts of 4 components , they are: 1. The interior renovaon of the northern mos t poron of the exis ng s chool building currently occupied by @Bat. This includes converng the space into 3 addional classrooms and res trooms . 2. The interior renovaon of the exisng strip center on the eas t s ide of the s ite. This renovaon w ould largely consist of 8 middle school clas s rooms , cafeteria, office space, s cience room, art room and restrooms. 3. Building addion to the northeas t s ide of the exisng strip center. The addion includes a lobby area, restrooms, s torage areas and an approximately 5,200 square foot gymnas ium. A s previously menoned, the property is z oned B-2 (D owntown Bus iness) and the propos ed addion meets all s etback and lot coverage requirements in the B-2 z one. 4. Removal of porons of the exis ng parking lot to create a courtyard to the s outh of the propos ed gymnas ium addion along with adding greenspace on the s outhern end of the exisng strip center building adjacent to the right-of-way of Elm S treet. City Code requires one parking stall be provided for each clas s room plus one parking stall per every 30 s tudents. The use as propos ed (school) would require 34 off-s treet parking stalls . The property currently has 229 off-s treet stalls w ithin its boundary. W ith the proposed building expansion and addion of greens pace menoned above this would remove 33 off-street parking s paces from this s ite. I f the plan w ere to be cons tructed as propos ed a total of 196 off-s treet parking stalls w ould be remaining on s ite. I t is ancipated that with the proposed expans ion the total s chool enrollment w ill increase to over 500 s tudents. O ff-street parking on s ite is sufficient to accommodate the propos ed use. W ith that being said, please note, that being the s ite is zoned B-2 (D ow ntow n Busines s ) it is exempt from the aforemenoned parking s tandards per code. A n updated traffic study w as performed for this condional use permit applicaon (s ee a7ached). The s tudy indicated that the addion of M iddle S chool traffic w ill increase the school related site traffic from 179 entering trips and 165 exing trips to 226 entering trips and 218 exing trips during the more intense A M peak. C ondional Use Permit A s outlined in C ity C ode, a condional use s hall be approved if it is found to meet the follow ing criteria: 1. The propos ed use conforms to the district permi7ed and condional use provis ions and all general regulaons of this tle. The use is listed as a C ondional U se w ithin the B-2 (D owntown Business) z oning district. 2. The propos ed use s hall not involve any element or caus e any condions that may be dangerous, injurious or noxious to any other property or pers on and shall comply w ith the performance s tandards listed below. The proposed use will not create any condion listed above. 3. The propos ed use s hall be cons tructed, des igned, sited, oriented and lands caped to produce harmonious relaonship of buildings and grounds to adjacent buildings and properes . M ost of the expansion will take place within exisng buildings with the excepon of the gymnasium expansion w hich w ill be located tow ards the center of the property. 4. The propos ed use s hall produce a total vis ual impres s ion and environment w hich is cons is tent with the environment of the neighborhood. M ost of the expansion w ill take place w ithin exisng buildings with the excepon of the gymnasium expansion. The expansion into the exisng strip center will displace four exisng businesses. 5. The propos ed use s hall organiz e vehicular access and parking to minimiz e traffic conges on in the neighborhood. Thus use will uliz e exisng site accesses along with exisng parking areas. 6. The propos ed use s hall preserve the objecves of this tle and s hall be cons is tent with the comprehens ive plan. The use is listed as a condional use w ithin the B-2 z oning district and is consistent with the comprehensive plan. A C T I O N R EQ U E S T E D A pprove the amendment to the condional us e permit to allow the expans ion of a school at the property located at 115 Elm S treet conngent upon the following: 1. The submis s ion and approval of all building and fire permits as deemed neces s ary for the expansion. 2. S ign permit s hall be s ubmi7ed and approved for any exterior s ignage to be placed on the buildings or s ite. AT TA C H M E N TS : Type D es cripon Backup M aterial S ite P lan Backup M aterial F loor P lans Backup M aterial Building Elevaon 1 Backup M aterial Building Elevaon 2 Backup M aterial Traffic S tudy Backup M aterial A lta S urvey Backup M aterial Le7ers of S upport TO :P lanning Commission F R O M :J ared J ohns on, P lanning Coordinator S U B J EC T:Request for a C ondional Use Permit to A llow the Construcon of a Ulity H ut within the I -I ndus trial Zoning D istrict DATE:M arch 14, 2023 I N T R O D U C TI O N A rvig, a telecommunicaons company, is requesng approval of a condional us e permit (C U P ) to cons truct a 336 s quare-foot ulity hut at the subject property addres s ed as 5000 208th S treet W. D I S C U S S I O N A rvig is looking to expand their fiber opc s ervices in the city and are proposing to build a 336 square- foot ulity hut on the property located at 5000 208th S treet W. This property is ow ned by X cel Energy and contains a power substaon. X cel Energy has agreed to let A rvig build the ulity hut on their property. Per City Code, ulity buildings require a C U P in the I (I ndustrial D is trict). The propos ed ulity hut w ould allow A rvig to connect into exis ng ulies and expand their s ervices . Zoning The property is located in the Farmington I ndus trial Park and is z oned I -I ndustrial. The C omprehens ive P lan guides the property for I ndustrial. P ublic ulity buildings are listed as a condional us e in the I -I ndus trial D istrict. The exisng use on the property is a power substaon and the propos ed ulity hut will not alter the use. The ulity hut meets all lot dimens ional requirements in the I -I ndus trial D istrict. S ite P lan The property is 11.63 acres and contains a pow er s ubs taon and open s pace. The pow er s ubs taon is located in the southwes t corner of the s ite and is enclosed by a chain link fence. The proposed ulity hut w ould be located near the northw est end of the site w here there is an exis ng gravel access drivew ay onto 208th S treet W. The ulity hut would include 989 s quare-feet of gravel parking area. A ccess The site is acces s ed off of 208th S treet W in the northwes t corner by a gravel acces s driveway. The Farmington Economic D evelopment A uthority (E DA ) owns a very narrow strip of land (16.5 feet w ide) in between 208th S treet W and the w estern property line of the site. X cel Energy obtained a license agreement in 2005 from the E DA in order to access the s ite and cons truct the pow er s ubs taon. A s a condion of approval, an addional license agreement will need to be executed with the E DA for A rvig to acces s and place fiber opc through the E DA owned land. Ulies The ulity hut is strategically placed near the access onto 208th S treet W. There are exisng ulity lines along the street that A rvig can connect into. A fiber opc line would run from the ulity hut, acros s the E DA land, and connect into an exis ng line at the end of 208th S treet W. Condional U s e Permit Review A s outlined in C ity C ode, a condional use permit shall be approved if it ’s found to meet the follow ing criteria: 1. The proposed us e conforms to the dis trict permi@ed and condional us e provisions and all general regulaons of this tle. The use is listed as a condional use w ithin the I -I ndustrial D istrict. C riterion met. 2. The proposed us e shall not involve any element or cause any condions that may be dangerous , injurious or noxious to any other property or pers ons and shall comply w ith the performance standards lis ted below. The proposed use w ill not create any condion listed above. C riterion met. 3. The proposed us e shall be constructed, designed, s ited, oriented and landscaped to produce harmonious relaonship of buildings and grounds to adjacent buildings and properes . The proposed use w ill be constructed, designed, sited, oriented and landscaped to produce harmonious relaonship of buildings and grounds to adjacent buildings and properes. C riterion met. 4. The proposed us e shall produce a total visual impression and environment which is consistent w ith the environment of the neighborhood. The proposed use w ill produce a total visual impression and environment consistent with the neighborhood. C riterion met. 5. The proposed us e shall organize vehicular acces s and parking to minimize traffic congeson in the neighborhood. The proposed use organizes vehicular access and parking to minimiz e traffic in the neighborhood. Criterion met. 6. The proposed us e shall pres erve the objecves of this tle and shall be consistent w ith the comprehens ive plan. T he proposed use is listed as a condional use within the I -I ndustrial District and is consistent with the comprehensive plan. C riterion met. A C T I O N R EQ U E S T E D A pprove the condional us e permit to allow the cons trucon of a ulity hut within the I -I ndus trial D istrict on the property addres s ed as 5000 208th S treet W conngent upon the following: 1. A license agreement to allow the access and placement of ulies through E DA owned land shall be executed and recorded prior to cons trucon. 2. S as facon of all Engineering comments. AT TA C H M E N TS : Type D es cripon Backup M aterial S ite P lans Backup M aterial Locaon M ap Backup M aterial E DA A erial T-1 TITLE SHEET DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , VICINITY MAP N.T.S. SITE LOCATION SITE LOCATION SITE NAME FARMINGTON REVISIONSHEETDRAWING INDEX N.T.S. ATTACHMENTS 22" x 34" IS FULL SCALE. 11" x 17" IS HALF SCALE. TERRA CONSULTING GROUP, LTD. 600 BUSSE HIGHWAY PARK RIDGE, IL 60068 (847) 698-6400 PROJECT CONSULTANT: CONSTRUCTION COMPANY CONTACT: CONSULTANT TEAM 5000 WEST 208TH STREET FARMINGTON, MN 55024 EQUIPMENT HUT INSTALLATION ARVIG LATITUDE: LONGITUDE: SITE ADDRESS:5000 WEST 208TH STREET FARMINGTON, MN 55024 (651)675-5000 DAKOTA COUNTYCOUNTY: PROJECT INFORMATION T-1 TITLE SHEET - C-1 ENGINEERING SITE PLAN - C-2 EROSION CONTROL PLAN - C-3 SITE GRADING PLAN - C-4 SHELTER ELEVATIONS 1 S-1 SITE DETAILS - N-1 GENERAL NOTES - 1.IN THE EVENT THAT SPECIAL INSPECTIONS ARE NOT PERFORMED IN COMPLIANCE WITH THE CONTRACT TERMS, BID SPECIFICATIONS AND/ OR SPECIFIED FORM, THE GENERAL CONTRACTOR WILL BE LIABLE FOR ALL DAMAGES, CONSTRUCTION PERFORMANCE, FAILURES, AND CORRECTIVE ACTIONS RELATED TO THE SAME. 2.THE FOLLOWING GENERAL NOTES SHALL APPLY TO DRAWINGS AND GOVERN UNLESS OTHERWISE NOTED OR SPECIFIED. 3.THE WORK DELINEATED IN THESE DRAWINGS AND DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO CODES, STANDARDS AND REFUTATIONS THAT HAVE JURISDICTION IN THE STATE OF MINNESOTA, AND THE CITY OF FARMINGTON. 4.REQUIREMENTS AND REGULATIONS PERTAINING TO R.F. SAFETY CODES AND PRACTICES MUST BE INCORPORATED IN THE WORK EVEN THOUGH THEY MAY HAVE NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN WITHER THE DRAWINGS OR THE SPECIFICATIONS. 5.COMPARE FIELD CONDITIONS WITH ARCHITECTURAL AND ENGINEERING DRAWINGS. ANY DISCREPANCIES SHALL BE DIRECTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO FABRICATION AND/ OR CONSTRUCTION. SUBMIT NECESSARY SHOP DRAWINGS PRIOR TO FABRICATION FOR APPROVAL BY THE ARCHITECT. NO INFORMATION OR DETAILS ON THESE SHEET MAY BE USED WITHOUT PERMISSION OF THE OWNER, OR THE ARCHITECT. 6.DO NOT SCALE DRAWINGS! 11"x17" DRAWINGS TO SCALE 24"x36" DRAWINGS SCALE MULTIPLY BY 2 7.UNLESS OTHERWISE SHOWN OR NOTED, TYPICAL DETAILS SHALL BE USED WHERE APPLICABLE. 8.DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR CONDITIONS. 9.SAFETY MEASURES:THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF THE PERSONS AND PROPERTY AND FOR INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S OR ENGINEERS' JOB SITE REVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 10.WITHIN THESE PLANS AND SPECIFICATIONS, "OWNER IMPLIES ARVIG COMMUNICATIONS. 11.THE WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 12.THE TERMS "CONTRACTOR" AND "G.C." REFER TO THE OWNER'S GENERAL CONTRACTOR AND THE GENERAL CONTRACTOR'S SUB-CONTRACTORS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE DIVISION OF WORK AMONG SUB-CONTRACTORS. 13.THE GENERAL CONTRACTOR IS RESPONSIBLE IN OBTAINING NECESSARY PUBLIC AND PRIVATE UNDERGROUND UTILITY LOCATE SERVICES PRIOR TO START OF EXCAVATING / CONSTRUCTION. 14.PRIOR TO START OF CONSTRUCTION THE CONTRACTOR SHALL VERIFY ALL SIZES OF EXISTING AND/ OR PROPOSED CONDUITS, PENETRATIONS, AND HAND HOLES THAT WILL BE UTILIZED FOR THE FIBER INSTALLATION ALONG WITH ALL OTHER MATERIALS NEEDED FOR INSTALLATION. 15.ON SITE CONDITIONS SHALL BE CONFIRMED PRIOR TO THE START OF CONSTRUCTION. 16.CONTRACTOR SHALL FOLLOW ALL LOCAL MUNICIPAL CODES FOR CONDUIT SPECIFICATIONS AND INSTALLATION. NORTHERN STATES POWER CO. 5000 208TH STREET WEST SITE OWNER: SITE AQ.:VINCO INC, 18995 FOREST BLVD. N. FOREST LAKE, MN 55025 (651) 982-4642 GENERAL NOTES 44° 38' 46.50" N (GOOGLE EARTH) 93° 9' 59.83" W (GOOGLE EARTH) PROJECT DESCRIPTION 1.PROPOSED INSTALLATION OF EQUIPMENT HUT REGIONAL MAP VINCO INC, 18995 FOREST BLVD. N. FOREST LAKE, MN 55025 (651) 982-4642 PHONE: (651) 982-4642 FAX: (651) 982-4261 FOREST LAKE, MN 55025 18995 FOREST BLVD. N., BOUNDARY SURVEY UGE UGE T T T T T T T T T T T T T T T T T T T G G G G G G G G G G G UGE UGE UGE UGE UGE UGE U G E U G E U G E U G E U G E UG E UG E UG E E E UGE UGE UGE UGE UGE UGE UGE UGE UG E UG E UG E U G E U G E x x x x x x x x x x x x x x x x x x x F F F F F F F F F F F F F F F F F F DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , 0 SC A L E : 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. 10'20'40' 1" = 2 0 ' ± CENTERLINE OF EASEMENT EXISTING CHAIN-LINK FENCE EXISTING PROPERTY LINE (TYP.) PROPOSED 12'x28' BULDING ON CONCRETE SLAB WITH 2' APRON ON ALL SIDES EXISTING TEMPORARY ACCESS EASEMENT PER DOC. NO. 2401502 E X I S T I N G G R A V E L D R I V E W A Y 208TH ST W EXISTING 100' WIDE GAS PIPELINE EASEMENT PER BOOK, 225, DEES, PAGE 358, AS AMENDED BY BOOK 68, MISC., PAGE 241 96 . 7 ' 36' SETBACK 35.7' 10 8 . 7 ' S E T B A C K PROPOSED GRAVEL PARKING AREA 989 SQUARE FEET SITE PLAN C-1 50 ' 50 ' EXISTING SYMBOLS & UTILITIES LEGEND LIGHT POLE UTILITY POLE WATER VALVE UNDERGROUND ELECTRIC ANCHOR HANDHOLE x x FENCE LINE ELECTRIC UGE UNDERGROUND FIBERUGF UNDERGROUND GAS LINEGAS OHE OHF OHT OVERHEAD ELECTRIC OVERHEAD FIBER OVERHEAD TELCO UTILITY LINE PROPOSED SYMBOLS & UTILITIES LEGEND STEEL POLEWOOD POLE STORM SEWER LINE SANITARY SEWER LINE TRANSFORMER WATERMAIN LINE SIGN CATCH BASIN DECIDUOUS TREE MONUMENT FOUND MANHOLE FIRE HYDRANT TRAFFIC LIGHT CURB STOP VALVE PEDESTAL UNDERGROUND FIBERUGFUGF UNDERGROUND POWERUGEUGE EXISTING GAS LINE PROPOSED 4" CONDUIT ROUTE PROPOSED 24" x 36" HAND HOLE (SEE DETAIL 2/S-1) PROPOSED 4" CONDUIT ROUTE F F F F F F F F F F F F F F F F F F F F DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , 1.SOIL DISTURBANCE SHALL BE CONDUCTED IN SUCH A MANNER TO MINIMIZE EROSION. AREAS OF THE DEVELOPMENT SITE THAT ARE NOT GRADED SHALL BE PROTECTED FROM CONSTRUCTION TRAFFIC OR OTHER DISTURBANCE UNTIL FINAL SEEDING IS PERFORMED. 2.PROPERTIES AND CHANNELS ADJOINING THE DEVELOPMENT SHALL BE PROTECTED FROM EROSION AND SEDIMENTATION. 3.SOIL EROSION AND SEDIMENT CONTROL FEATURES SHALL BE CONSTRUCTED PRIOR TO THE COMMENCEMENT OF HYDROLOGIC DISTURBANCE OF UPLAND AREAS. 4.DISTURBED AREAS SHALL BE STABILIZED WITH TEMPORARY OR PERMANENT MEASURES WITHIN FOURTEEN (14) CALENDAR DAYS FOLLOWING THE END OF ACTIVE HYDROLOGIC DISTURBANCE. 5.IF DEWATERING SERVICES ARE USED, ADJOINING PROPERTIES AND DISCHARGE SHALL BE PROTECTED FROM EROSION. DISCHARGES SHALL BE ROUTED THROUGH AN EFFECTIVE SEDIMENT CONTROL MEASURE. (E.G., SEDIMENT TRAP, SEDIMENT BASIN, OR OTHER APPROPRIATE MEASURES). 6.ALL TEMPORARY SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN THIRTY (30) DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED. TRAPPED SEDIMENT AND OTHER DISTURBED SOIL AREAS SHALL BE PERMANENTLY STABILIZED. 7.SOIL STOCKPILES SHALL NOT BE LOCATED IN A FLOOD-PRONE AREA OR DESIGNATED BUFFER PROTECTING WATERS OF THE UNITES STATES OR ISOLATED WATERS OF THE COUNTY. CONTRACTOR TO USE SOILS EXCAVATED FROM THE LEASE SITE AND USE TO BUILD UP THE DEPRESSIONAL STORAGE BASIN. 8.THE CONTRACTOR SHALL PROVIDE ADEQUATE RECEPTACLES FOR THE DEPOSITION OF ALL CONSTRUCTION MATERIAL DEBRIS GENERATED DURING THE DEVELOPMENT PROCESS. THE CONTRACTOR SHALL NOT CAUSE OR PERMIT THE DUMPING, DEPOSITING, DROPPING, THROWING, DISCARDING OR LEAVING OF CONSTRUCTION MATERIAL DEBRIS UPON OR ONTO ANY DEVELOPMENT SITE, CHANNEL, WATERS OF THE U.S. OR ISOLATED WATERS OF THE COUNTY. THE CONTRACTOR SHALL MAINTAIN THE DEVELOPMENT SITE FREE OF CONSTRUCTION MATERIAL DEBRIS. 9.ALL TEMPORARY AND PERMANENT EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED IN AN EFFECTIVE WORKING CONDITION. 10.STREET SWEEPING SHALL OCCUR DAILY DURING CONSTRUCTION ACTIVITY OR AS REQUESTED BY CITY ENGINEER. 11.DUST CONTROL AND WATERING TO OCCUR AS NEEDED OR REQUESTED BY CITY ENGINEER. 12. HOURS OF CONSTRUCTION OPERATION FROM 7AM TO 7PM MONDAY THROUGH SATURDAY PER CITY CODE. EROSION CONTROL NOTES: NATURAL SOIL FLOW WIRE MESH REINFORCEMENT (OPTIONAL) METAL OR WOOD POST OR STAKE SUPPORT POST ANCHORAGE FROM IN-SITU SOIL TO CEMENT MORTAR GEOTEXTILE FABRIC FABRIC ANCHORAGE TRENCH BACKFILL W/TAMPED NATURAL SOIL NOTE: DEPENDING UPON CONFIGURATION, ATTACH FABRIC TO WIRE MESH W/HOG RINGS, STEEL POSTS W/ TIE WIRES, WOOD POSTS W/ NAILS. DIRECTION OF RUNOFF 6" MIN.6" N.T.S. LEGEND EROSION CONTROL BLANKET & SEEDING (NATIVE GRASSES) EXISTING GROUND DIRECTION EROSION CONTROL SILT FENCE B.R.BIOROLL DITCH CHECK (SEE DETAIL) o o o o o o ooo o o o o o ooo o o o o o oo GEO-SYNTHETICS, INC. 428 N. PEWAUKEE ROAD WAUKESHA, WI. 53188 (414) 524-7979 800-444-5525 NOTE: DIMENSIONS VARY, AS NEEDED TO FIT STRUCTURES SHOWN OR EQUIVALENT 36" 33" 30" 6" (TYP.) 6" GSI (TYP.) (TYPAR 3201 FABRIC) N.T.S. EROSION CONTROL FILTER BASKET F.B. EROSION CONTROL FILTER BASKET (SEE DETAIL) EROSION CONTROL SILT FENCE DETAIL 6" OF TOPSOIL & SEEDING (NATIVE GRASSES) NATIVE GRASS/FORB PLANTING & SEEDING (NATIVE GRASSES) I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. NAME: ___________________ DATE:___________ LICENSE #:___________XX-XX-XX EROSION CONTROL PLAN C-2 0 SC A L E : 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. 5'10'20' 1" = 1 0 ' ± ooo o o o o o o T T T U G E U G E U G E U G E U G E U G E U G E U G E U G E F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , 1 SCALE: 1" = 10' SITE GRADING PLAN SITE GRADING PLAN (SHEET 1 OF 1) C-3 0.00% 000 PROPOSED ELEVATION DRAINAGE DIRECTION ARROW PROPOSED CONTOUR EXISTING CONTOUR PROPOSED CULVERT & END SECTIONS PROPOSED GROUND RIDGE LINE EXISTING GROUND DRAINAGE FLOW DIRECTION GROUND SLOPE% WITH DIRECTION SUMMIT DRAINAGE DIRECTIONS PROPOSED GROUND DRAINAGE FLOW DIRECTION ARROWS 0000.00 000 PROPOSED SPOT GRADES PROPOSED LINES LEGEND 0 SC A L E : 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. 5'10'20' 1" = 1 0 ' ± T T T T T G G G G G T T T T T G G G G G E E DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , SHELTER ELEVATIONS C-4 1 SCALE: 1" = 2' ELEVATION A 2 SCALE: 1" = 2' ELEVATION B 3 SCALE: 1" = 2' ELEVATION C 4 SCALE: 1" = 2' ELEVATION D 6" 9' - 0 " 7" 10 ' - 1 " 14'-2" 28'-4" 1' - 4 1 2" 6" 9' - 0 " 6" 10 ' - 0 " 11'-9" 5'-81 2" 1' - 1 1 1 2" 1'-4"1'-4" 3' - 1 " 4" 10 " 10 " 2'-31 4" 6" 9' - 0 " 7" 10 ' - 1 " 4'-11" 28'-4" 1' - 4 1 2" 2'-2" 2'-5" 11'-9" 2'-5" 5'-81 2" 1' - 1 1 1 2" 6" 9' - 0 " 6" 10 ' - 0 " JUNCTION BOX ELECTRIC METER JUNCTION BOX 2" RISE CONDUIT 1.25" GROUND CONDUIT 2" RISE CONDUIT 1.25" GROUND CONDUIT DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , CONDUIT SIZE, TYPE, QUANTITY AND SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS CONDUITS FOR ELECTRICAL & ANTENNA SHARING WHERE APPLICABLE UNDISTURBED SOIL RETURN ORIGINAL MATERIAL TO TRENCH, COMPACT TO MAXIMUM DENSITY IN ACCORDANCE WITH ASTM D1557 COMPACTED SAND (SEE NOTE 1) COMPACTED SAND BED (SEE NOTE 1) PROVIDE PANDUIT UNDERGROUND HAZARD TAPE (FOIL TYPE) 'CAUTION-ELECTRICAL LINE BURIED BELOW' AT 1'-0" ABOVE SAND FOR THE ENTIRE LENGTH OF THE CONDUIT RUN LC CA-17 COARSE AGGREGATE COMPACTED TO 90% STANDARD PROCTOR 12" (MIN) SEPARATION 4" 4" 42 " TRENCH 3. 1 SCALE: N.T.S. UTILITY TRENCH DETAIL RESTORE SURFACE COARSE MATERIAL AND BASE COARSE TO ORIGINAL CONDITION AFTER INSTALLATION OF UTILITIES. GRADE SURFACE TO LEVEL. LEAN CONCRETE, RED-COLORED TOP, MAY BE USED IN PLACE OF COMPACTED SAND. BURY CONDUITS 42" BELOW GRADE OR 6" BELOW FROST LINE, WHICHEVER IS GREATER 1. 2. NOTES: SITE DETAILS S-1 SCALE: N.T.S. VAULT PULL BOX DETAIL 3/8 - 7 LAG THREAD SELF ALIGNING REPLACEABLES S.S. EZ-NUT (TYP. OF 2) 36"24 " 3/8 - 7 LAG THREAD X 2 [51] S.S. HEX HEAD CAPTIVE BOLT (TYP. OF 2) 3/8 [10] S.S. FLAT WASHER (TYP. OF 2) 1/2"Ø THRU HOLE WITH 1"Ø X 3/8" DEEP COUNTERBORE SKID RESISTANT SURFACE MS-86 TELEPHONE MARKER 1" X 4" PULL SLOT WITH 1/4"Ø CENTER PIN NOTE: ALL STUB-UP CONDUITS INSIDE PULL BOXES WILL BE 6" FROM TOP OF BOX AND HAVE PULL STRINGS AND CAPS 24 " 2 DE S C R I P T I O N RE V I S I O N S SHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY: NO . BY DA T E -0 1 IS S U E D F O R R E V I E W IS S U E D F O R F I N A L AD D I T I O N O F S H E L T E R E L E V A T I O N S 02 / 0 9 / 2 3 02 / 1 0 / 2 3 02 / 1 6 / 2 3 KS S KS S KS S FARMINGTON 5000 208TH ST W FARMINGTON, MN 55024 KSS SC 01/30/23 128-032 PR E P A R E D F O R PH O N E : ( 6 5 1 ) 9 8 2 - 4 6 4 2 F A X : ( 6 5 1 ) 9 8 2 - 4 2 6 1 FO R E S T L A K E , M N 5 5 0 2 5 18 9 9 5 F O R E S T B L V D . N . , N-1 GENERAL NOTES Subject Property – 5000 208th Street W TO :P lanning C ommis s ion F R O M :Tony W ippler, P lanning M anager S U B J EC T:Variance Requests to M inimum Lot S ize w ithin the A -1 Zone - Patrick & D awn D evney DATE:March 14, 2023 I N T R O D U C TI O N The applicants, Patrick and D aw n D evney, are s eeking variances from the minimum lot size requirement in the A gricultural Zoning D is trict (A -1) to subdivide/s plit tw o exis2ng parcels . The minimum lot size w ithin the A -1 zoning dis trict is 40 acres . The subject parcels to be split are legally described as follow s : (1) Tract B, Registered L and Survey N o. 66 (P I D 14-63190-00-022) 63.97 acres. T he applicant is proposing to split off 18.033 acres. (2) Tract G , Registered Land S urvey No. 66 (P I D 14-63190-00-070) 153.1 acres. The applicant is proposing to s plit off 1.967 acres. The split of the parcels is being necessitated by the dissolving of D evenshire Farms G eneral Partners hip (ow ners of the proper2es ). D ue to this ac2on, the splits as proposed (in total 20 acres ) is part of the payment to the applicants. P lanning D ivision Review A pplicant: Patrick and D aw n D evney 19192 C oAage Road Farmington, M N 55024 Property O wner: J M A D evney Family, L L P 5788 212th S treet W Farmington, M N 55024 Property L oca on: Generally located at the southwest intersec2on of Pilot Knob Road and C S A H 50 (see aAached aerial). Exis ng Lot S ize: -Tract B, Regis tered L and S urvey No. 66 - 63.97 acres -Tract G , Registered Land S urvey No. 66 - 153.1 acres Proposed Lots a&er S ubdivision: Tract B s plit - 45.937 acres and 18.033 Tract G split - 151.133 and 1.967 (s ee aAached cer2ficate of s urvey) Exis ng Z oning: A -1 (A griculture) 2040 Comprehensive P lan: A griculture Exis ng Land Use: Cul2vated farmland S urrounding Land Uses: Cul2vated farmland to the north, s outh, and w est. V ita AFva res iden2al subdivis ion to the east. D I S C U S S I O N A s previously men2oned, the applicants are seeking to split off a total of 20 acres (18.033 acres and 1.967 acres ) between two exis 2ng parcels. Both of the new parcels to be created by the split are less than the required minimum parcel size w ithin the A -1 zone - 40 acres thus requiring approval of variances . The exis 2ng parcels aGer the split will s2ll be over the minimum 40 acre requirement (45.937 acres and 151.133 acres ). The minimum lot size requirement for proper2es w ithin the A -1 zoning dis trict was amended in May of 2002. The previous minimum lot area requirement was one (1) acre and was changed to 40 acres . The P lanning Commission has granted s everal variances from the minimum lot s iz e requirement in the A - 1 z oning district s ince the code was amended in 2002. The follow ing is a lis t of thos e proper2es : Mals z ycki 8-11-09 (tw o 1 acre parcels ) A pproved Pat D onnelly 10-10-06 (5 acre) A pproved I S D #192 10-10-06 (18.4 acre) A pproved Terry D onnelly 6-10-03 (5 acre) A pproved K indseth 2-11-03 (1.42 and 1.69 acres ) A pproved Ben Ward 1-14-03 (4.71 acres) A pproved Bob D onnelly 12-10-02 (30 acres) A pproved S taff is s ugges2ng if the variances are approved by the P lanning C ommis s ion that a lot combina2on be done through D akota County for the 1.967 acre parcel and the 18.033 acre parcel. The lot combina2on w ould have to be done aGer the waiver of plat is adminis tra2vely approved by city s taff. The Board of A djustment shall not approve any variance reques t unless they find that "prac2cal difficul2es" exis t us ing the follow ing criteria: 1. Because the par2cular physical s urroundings, or the s hape, configura2on, topography, or other condi2ons of the s pecified parcel of land involved, s trict adherence to the regula2ons of this 2tle w ould cause prac2cal difficul2es. Economic cons idera2on alone does not cons2tute prac2cal difficul2es. The city code was amended in M ay of 2002 to increase the minimum lot area required for properes in the A-1 zoning district from one (1) acre to 40 acres. I f the code amendment had not occurred, the applicants could proceed with a plat and be in compliance w ith the zoning code. The amendment to the code, therefore, may have caused praccal difficules to the applicants. P revious variances similar in nature have been approved. 2. That the variance would be cons is tent with the comprehens ive plan. S taff believes the variances w ould be consistent w ith the C omprehensive P lan. 3. That the variance would be in harmony w ith the general purposes and intent of this 2tle. S taff believes the variances to be in harmony w ith the general purposes and intent of this tle. 4. The condi2ons upon w hich a variance is based are unique to the parcel of land for w hich the variance is sought and are not applicable, generally, to other proper2es within the s ame zoning classifica2on. W hen the city code w as amended to increase the minimum lot size in the A-1 z oning district, several properes became nonconforming. The majority of properes in the A-1 z oning district how ever do comply with the minimum lot siz e thus creang a similar situaon to the applicants for only a minority of property ow ners in the A-1 zoning district. 5. The alleged difficulty or hards hip is caused by this 2tle and has not been created by any pers ons having an interest in the parcel of land. The hardship or difficulty, if determined by the P lanning C ommission to exist, w as not created by the applicants or any other person having an interest in the property. 6. The gran2ng of the variance w ill not alter the essen2al character of the locality or be injurious to other property in the vicinity in which the parcel of land is located or substan2ally diminis h property values. G ranng the variances would not alter the character of the area or have a negave impact on other property in the vicinity. 7. The propos ed variance w ill not s ubs tan2ally increase the conges2on of the public streets , or increase the danger of fire, or be detrimental to the public w elfare or public safety. The proposed variances would not result in any of the above menoned adverse effects. 8. The reques ted variance is the minimum ac2on required to eliminate the prac2cal difficul2es . The P lanning C ommission must determine whether granng the variances to create two substandard parcels is the minimum variance that w ould eliminate the potenal difficulty. 9. Variances may not be approved for any us e that is not allowed under this 2tle for property in the z one where the affected person's land is located except that the temporary us e of a one-family dw elling as a tw o-family dwelling may be authorized by variance. The use of the property will connue to be culvated farmland which is permi2ed in the A-1 z oning district. A C T I O N R EQ U E S T E D A pprove the variances allow ing the crea2on of a 1.967 acre parcel and a 18.033 acre parcel within the A -1 z oning district s ubject to the following con2ngencies : 1. S ubmission and approval of a Waiver of P lat applica2on. 2. A lot combina2on through D akota County must be completed combining the 1.967 acre parcel with the 18.033 acre parcel. AT TA C H M E N TS : Type D es crip2on Backup M aterial S ite A erial Backup M aterial Cer2ficate of S urvey Dakota County, MN Disclaimer: Map and parcel data are believed to be accurate, but accuracy is not guaranteed. This is not a legal document and should not be substituted for a title search,appraisal, survey, or for zoning verification. Map Scale 1 inch = 1200 feet 3/8/2023